OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 91 of 173
H20411-0e-ID-B.docx
Notes:
•
The blue LED on ID ISC.ANTS370270 need a active H-field and must be confi-
gured in
OUT-S:
OUT-S (Output State) defines the status of the output during the time defined in OUT-
TIME and provides the possibility to allocate its own flashing-frequency to each output.
Bit:
7
6
5
4
3
2
1
0
Function: 0 0 0 0 OUTx-frq OUTx-mode
°
OUTx-mode:
b00
UNCHANGED
OUT-TIME has no effect on the status of the output
b01
ON
output for OUT-TIME = active
b10
OFF
output for OUT-TIME = inactive
b11
FLASH
output for OUT-TIME = with OSF alternating
OUTx-frq:
b11 1
Hz
b10 2
Hz
b01 4
Hz
b00 8
Hz
OUT-TIME:
By the values defined by “OUT-TIME”, the outputs can be activated temporary limited or
unlimited.
An exception are the time values 0 and 65535 (0xFFFF) (see following table).
0x0001
1 x 100ms
-> 100ms
... ...
0xFFFE
65534 x 100ms -> 1:49:13 h
0xFFFF
continuously active
Notes:
•
In order to reset a continuously active time, OUT-TIME = 1 has to be sent to
the
Reader, which effects a change to the idle status after 100 ms.
•
The continuous activation is being set back after a reset or a power failure.