0x83
RF communication error:
This error indicates that there is an error in communication between the Transponder and
the Reader. Reason for this can be:
•
The collision handling algorithm was not continued until no collision is detected,
reasons for the break:
- TR-RESPOSE-TIME in CFG1: Interface is to short
- Transponder is in the in the limit reading range
- to much noise in the antenna field
0x84
RF-Warning:
Detailed status information can be read with the command
.
•
The antenna configuration isn’t correct. Check the antenna cables and the anten-
na matching.
•
The environment is too noisy.
•
The RF power doesn’t have the configured value.
0x92
No valid Data:
•
There is no valid data in the Buffered Read Mode.
•
There is no Transponder in the antenna field.
•
The
VALID-TIME
hasn’t elapsed for Transponders in the antenna field.
0x93
Data Buffer Overflow:
•
A data buffer overflow occurred.
0x94
More Data:
•
There are more Transponder data sets requested than the response protocol can
transfer at once.
0x95
Tag Error
•
A Tag error code was sent from the transponder. The Tag error code is shown in
the following byte.
Tag Errors for ISO15693 and ISO18000-3M3 Transponder are listed below.
27
see 5.9. CFG11: Read Mode