OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 28 of 173
H20411-0e-ID-B.docx
To change the READER-ID
you must write to the CFG0 immediately after the Login to the Reader
with the command
Notes:
•
A READER-ID = 0x00000000 disables the password function.
•
A read with the command Fehler! Verweisquelle konnte nicht gefunden werden.
will always get ‘0x00000000’.
•
A changed password becomes valid after a Reader reset.
•
The command doesn’t change the CFG0 register if all configuration blocks are
used.
•
The command
is used to enable configuration data
access.
•
It is possible to disable the READER-ID with an activation code, if the READER-
ID is unknown. The activation code must be ordered by your supplier or FEIG
Electronic GmbH.
Config Protection
By means of Config Protection, the access to the configuration parameters stored within the Read-
er
is protected by a 32-bit password, the "READER-ID". This means that only after a "Login" with a
valid READER-ID with the command
can configuration parameters in
the EEPROM of the Reader may be read and changed in the EEPROM of the Reader.