OBID
i-scan
®
UHF
Installation
ID ISC.MRU102-PoE/-USB
FEIG ELECTRONIC GmbH
Page 13 of 21
M20711-0e-ID-B.docx
4.4. Ethernet-Interface on X4 (10/100Tbase)
The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on
X4 and has an automatic “Crossover Detection” according to the 100BASE-T Standard.
With structured cabling CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps
or 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address. Interface parameter can be configured via soft-
ware protocol (e.g. ISOStart).
Network
Address
IP-Address
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
DHCP
OFF
Table 7: Standard factory configuration of the Ethernet connection
NOTE:
The reader provides a DHCP able TCP/IP interface.
It is recommended to use a shielded twisted pair STP CAT5 cable.