OBID
i-scan
®
Installation
ID ISC.MR101-USB / ID ISC.PR101-USB
FEIG ELECTRONIC GmbH
Page 11 of 20
M50805-4e-ID-B.doc
3.6. Starting
The reader must be registered to the operating system by the first use. To do this you should read
the manual “Installation OBID USB-driver“.
3.6.1. ID ISC.MR101
For registering the reader to the operating system, the reader must be connected to the power
supply and the USB-cable. In which order the cables are connected will remain left to the user. The
reader should not be used without connected antenna. Due to the reader uses an external power
supply a “Low Powered Interface” is sufficient. The maximum current through the USB-Interface
amounts to 100mA.
3.6.2. ID ISC.PR101
If the reader is connected with the USB-Interface of the computer by using an USB-cable, it regis-
ters in the operating system automatically. The power requirement of the reader amounts to more
than 100mA. The USB-Interface must be a High Powered Interface. A High Powered Interface
supports the reader up to 500mA.
Note:
The function of the reader is only guaranteed if it is connected to a High Powered Interface.