FEIG ELECTRONIC GmbH 

Page 5 of 27 

M20301-4e-ID-B.doc 

 

Safety Instructions / Warning - Read before start-up ! 

  The device may only be used for the purpose intended by the manufacturer. 

  The operation manual should be kept readily available at all times for each user. 

  Unauthorized changes and the use of spare parts and additional devices which have not been 

sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such 
unauthorized measures shall exclude the manufacturer from any liability. 

  The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid 

for the device. The manufacturer shall  not be held legally responsible for inaccuracies, errors, 
or omissions in the manual or automatically set parameters for a device or  for an incorrect 
application of a device. 

  Repairs may only be undertaken by the manufacturer. 

  Installation, operation, and maintenance procedures should only be carried out by qualified 

personnel. 

  Use of the device and its installation must be in accordance with national legal requirements 

and local electrical codes . 

  When working on devices the valid safety regulations must be observed. 

  Before touching the device, the power supply must always be interrupted. Make sure that the 

device is without voltage by measuring. The fading of an operation control (LED) is no indicator 
for an interrupted power supply or the device being out of voltage! 

  Special advice for wearers of cardiac pacemakers: 

Although this device doesn't exceed the valid limits for electromagnetic fields you should keep 
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in 
the immediate proximity of the device’s antenna for any length of time. 

 

Summary of Contents for OBID i-scan ID ISC.M02

Page 1: ...INSTALLATION MANUAL final public B 2016 03 17 M20301 4e ID B doc ID ISC M02 English...

Page 2: ...useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and...

Page 3: ...3 2 1 Supply voltage 10 3 2 2 RS232 interface TTL 11 3 2 3 Data Clock interface 12 3 2 4 Optional Security Module ID SAM M02 13 3 3 Display elements 14 3 4 Operating elements 15 3 4 1 Operating Progra...

Page 4: ...OBID i scan HF Installation ID ISC M02 FEIG ELECTRONIC GmbH Page 4 of 27 M20301 4e ID B doc 4 3 2 Canada IC approved antennas 24 4 4 Label Information Reader ID ISC M02 B 25 5 Technical Data 26...

Page 5: ...tically set parameters for a device or for an incorrect application of a device Repairs may only be undertaken by the manufacturer Installation operation and maintenance procedures should only be carr...

Page 6: ...is designed for reading and writing passive transponders so called Smart Labels with an operating frequency of 13 56 MHz It is suitable for any application in which short read ranges and small reader...

Page 7: ...mm 3 94inch x 3 94inch ID ISC ANT40 30 A PCB Antenna 50 40mm x 30mm 1 57inch x 1 57inch 2 3 Scope of delivery The following components are included Module type Included ID ISC M02 B 1 x Reader Module...

Page 8: ...M20301 4e ID B doc 3 Installation and wiring 3 1 Dimensions Fig 1 shows the dimensions of the ID ISC M02 Reader Module in mm Fig 1 Dimensions of the ID ISC M02 Reader Module in mm 26 1 2 1 3 3 3 3 3 3...

Page 9: ...X1 Pin no Function Description ID ISC M02 B 1 DAT Data line for the data clock interface 2 CLK Clock line for the data clock interface 3 TxD RS232 TTL Transmit Data 4 GND GND 5 RxD RS232 TTL Receive...

Page 10: ...equate filtering Noise from the power supply can result in a reduction of the read write range of the module The cable length from the power supply should be as short as possible and should in any cas...

Page 11: ...er Module Table 3 Pin assignments for the RS232 interface on X1 The transmission parameters for the interface can be software configured Table 4 shows the standard parameters for the RS232 interface P...

Page 12: ...X1 Pin no Function Description ID ISC M02 B 1 DAT Data line for the data clock in terface 2 CLK Clock line for the data clock interface 7 CLS CLS line for the data clock in terface 4 9 GND GND GND Pin...

Page 13: ...optional ID SAM M02 Security Module can be connected to terminals X3 and X4 The ID SAM M02 Security Module provided additional security by using cryptographic data trans mission between the reader an...

Page 14: ...ions of both LEDs can be configured using software protocol It is also possible to control both LEDs directly using an additional software protocol Table 3 3 1 shows the standard setting for V1 and V2...

Page 15: ...r starts after a reset Since the reader s firmware however also has a software bootloader the hardware bootloader option should be used only for installing the software bootloader For additional infor...

Page 16: ...the internal antenna to the driver circuit of the reader To connect an external antenna both jumpers J2 and J3 must therefore be removed Jumpers J2 and J3 Description in Internal antenna connected ou...

Page 17: ...scilloscope probe with the probe point and hold it over the circuit board of the ID ISC M02 The probe then forms a measuring loop for the radiated magnetic field of the ID ISC M02 The distance between...

Page 18: ...the trim capacitor Beschriftung Minimale Kapazit t Maximale Kapazit t Fig 10 Minimum and maximum position of the trim capacitor C65 After the antenna has bee tuned check it again for maximum range and...

Page 19: ...stances for the reader The distance between the reader and a metal surface should be at least 3 cm Note that even other circuit boards may act line metal objects depending on how much copper they cont...

Page 20: ...ion of a magnetic field alternating magnetic fields in the vicinity of the an tenna can have a negative impact on its function Sources of such magnetic interference fields include coils within a prima...

Page 21: ...4e ID B doc 4 Radio Approvals 4 1 Europe CE When used according to regulation this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R TTE Guid...

Page 22: ...OBID i scan HF Installation ID ISC M02 FEIG ELECTRONIC GmbH Page 22 of 27 M20301 4e ID B doc 4 2 Declaration of Conformity...

Page 23: ...ot installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful inte...

Page 24: ...identify the device by certification number or model number if Category II has been approved by Industry Canada to operate with the antenna types listed below with maxi mum permission gain and requir...

Page 25: ...scan HF Installation ID ISC M02 FEIG ELECTRONIC GmbH Page 25 of 27 M20301 4e ID B doc 4 4 Label Information Reader ID ISC M02 B The following label is positioned on the backside of the reader ID ISC...

Page 26: ...7 x 1 97 x 0 55 inch Weight 14g 0 03lb Connector 10 Pin Connector spacing 2 54mm 0 1inch Electrical Data Supply voltage ID ISC M02 B 5 V DC 5 Current draw max 200mA Power consumption max 1 Watt Operat...

Page 27: ...e 1 Code UID I Code EPC with separate firm ware and Upgrade Code ISO18000 3M3 with separate firmware and Upgrade Code EEPROM for parameters 1 kB 10 000 write cycles FLASH 64 kB for Parameter firmware...