8.1.4. Connection with External Powered Supply

Ethernet

ID CPR.IO

ID CPR50.10-E

Door Contact

X3

4
3
5
6
1
2

+

-

NOTICE:

 

Use only regulated power supply’s.

 

Reversing the polarity of the supply voltage may destroy the device.

 

Supply voltages outside the specifications may destroy the device.

 

If switching power supplies are used with the module, be sure that there is adequate fil-
tering. 

 

Noise from the power supply can result in a reduction of the read/write range of the

module.

Summary of Contents for OBID classic-pro Series

Page 1: ...INSTALLATION preliminary public B 2009 10 07 M90701 1de ID B FCC doc OBID classic pro ID CPR50 10 xE E SE RE SRE RFID Reader for ISO IEC14443 A B NFC and ISO IEC15693 with Ethernet Interface deutsch...

Page 2: ...OBID classic pro Montage ID CPR50 10 E RE FEIG ELECTRONIC GmbH Seite 2 von 39 M90701 1de ID B FCC doc D E U T S C H...

Page 3: ...OBID classic pro Montage ID CPR50 10 E RE FEIG ELECTRONIC GmbH Seite 3 von 39 M90701 1de ID B FCC doc D E U T S C H deutsche Version ab Seite 4 english version from page 22 E N G L I S H...

Page 4: ...okument gemachten Installationsempfehlungen gehen von g nstigsten Rahmenbedingun gen aus FEIG ELECTRONIC GmbH bernimmt weder Gew hr f r die einwandfreie Funktion in system fremden Umgebungen noch f r...

Page 5: ...O Modul 12 4 1 3 Anschluss ber PoE Netzteil 13 4 1 4 Anschluss einer externe Spannungsversorgung 14 4 1 5 Anschl sse des externen I O Moduls ID CPR I O A 15 4 1 5 1 Relais ID CPR I O A 15 4 1 5 2 Dig...

Page 6: ...ltigen Fassung F r eine ungeeignete falsche manuelle oder au tomatische Einstellung von Parametern f r ein Ger t bzw ungeeignete Verwendung ei nes Ger tes wird keine Haftung bernommen Reparaturen d r...

Page 7: ...ronik 1 x Aufputzadapter 1 x Anschlussplatine 1 x Linsenschraube Torx 3 x 8 mm Torx T10 zum Verschlie en des Geh uses 2 x Schneidschraube Senkkopf 3 2 x 15 mm zur Montage von Geh useunterteil auf Aufp...

Page 8: ...10 E kann im Polling oder Notification Mode betrieben werden Der Notification Mode reduziert den Datenverkehr auf der Ethernet Schnittstelle auf ein Minimum Im Notification Mode sendet der Reader aut...

Page 9: ...oberfl che sollte die Montage mit dem Aufputzadapter erfol gen damit ein ausreichender Abstand zwischen Leser und Metalloberfl che hergestellt ist Beim Einbau des Readers in einen Metallrahmen ist dar...

Page 10: ...seunterteil auf der Wand verschrauben Montagerichtung TOP beachten siehe Kapitel 4 Montage Geh useoberteil gerade auf das Geh useunterteil aufstecken und einrasten Stiftleiste X1 der Leserelektronik s...

Page 11: ...r das Auflegen der CAT5 Kabel auf der LSA Anschlussleiste ist ein entsprechendes LSA Auflege werkzeug punch down tool zu verwenden Abbildung 7 ID CPR50 10 E Adapter Platine mit LSA Anschlussleiste X2...

Page 12: ...ul ID CPR I O A angeschlossen werden Siehe 4 1 5 Anschl sse des externen I O Moduls ID CPR I O A Alternativ kann der Reader ID CPR50 10 RE mit einem internen Relais benutzt werden X3 Signal Beschreibu...

Page 13: ...e 13 von 39 M90701 1de ID B FCC doc D E U T S C H 4 1 3 Anschluss ber PoE Netzteil In diesem Verdrahtungsbeispiel wird der Reader ber ein PoE Netzteil mit Spannung versorgt PoE Power Supply IEEE802 3a...

Page 14: ...2 HINWEIS Nur geregelte Spannungsquellen verwenden Eine Verpolung der Versorgungsspannung kann zur Zerst rung des Ger tes f hren Versorgungsspannungen au erhalb der Spezifikation k nnen zur Zerst run...

Page 15: ...Beschreibung Verbunden mit Pin x on X3 CPR50 10 E 1 GND Ground 6 GND D 2 VCC 5 VDC 5 VCC 3 RxD Receive Input 4 OUT 4 TxD Transmit Output 3 IN 5 IN1 Digitaler Eingang 1 6 IN2 Digitaler Eingang 2 7 Rel...

Page 16: ...l sselte serielle Schnittstelle Die Kommunikationsverbindung zum Reader ID CPR50 10 E wird ber die Anschl sse RxD Pin3 und TxD Pin4 hergestellt Abbildung 9 Kommunikationsverbindung zum Reader ID CPR50...

Page 17: ...kation zwischen Reader und Transponder 4 2 1 EMV Beeinflussung ber Zuleitungen Trotz internen EMV Filter k nnen starke St rungen auf der Spannungsversorgung zu Beeintr chti gungen der Kommunikation zw...

Page 18: ...z Sendeleistung 250 mW 2 dB RF Interface ISO14443 A ISO14443 B NFC 1 ISO15693 Unterst tzte Transpondertypen z B mifare classic mini 1k 4k mifare UltraLight mifare DESfire Smart MX my d proximity SLE44...

Page 19: ...ved by the party responsible for compliance could void the user s authority to operate this equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital devi...

Page 20: ...llowing two conditions 1 this device may not cause interference and 2 this device must accept any interference including inter ference that may cause undesired operation of the device Usually this is...

Page 21: ...doc D E U T S C H 5 5 Abmessungen X1 1 84 2 mm 84 2 mm 60 0 mm 60 0 mm 77 7 mm 56 8 mm 60 0 mm 28 4 mm 28 4 mm 77 7 mm Abbildung 11 Unterputzgeh use Befestigungsmasse Abbildung 12 Aufputzadapter Befe...

Page 22: ...oundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which...

Page 23: ...30 8 1 3 Connection with PoE Supply 31 8 1 4 Connection with External Powered Supply 32 8 1 5 Connections of the extension IO Board ID CPR I O A 33 8 1 5 1 Relay ID CPR I O A 33 8 1 5 2 Digital input...

Page 24: ...chase are valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrec...

Page 25: ...Housing upper part with Reader electronic 1 x Surface mounting adapter 1 x Connection board 1 x Screw Torx 3 x 8 mm Torx T10 for closing the housing 2 x Thread cutting screws 3 2 x 15 mm for mounting...

Page 26: ...CPR50 10 E can work in polling mode or in notification mode which reduces the necessary data traffic with the reader to a minimum In notification mode the host will be informed by a notifi cation mes...

Page 27: ...detection range of the Reader If the reader is installed in a metal frame it must be ensured that a minimum distance of 25mm to the reader is observed Closed metal frame loop must be interrupted on o...

Page 28: ...m part of casing to selected surface Take care about the mounting direction TOP see chapter 8 Installation Put the casing upper part straight onto its bottom part and snap it in see Fig 5 Insert the p...

Page 29: ...pplying the CAT5 cable on to the LSA connector a special LSA punch down tool must be used Fig 7 ID CPR50 10 E connection board with LSA terminal X2 There are existing two different ways for the connec...

Page 30: ...r nal I O Module ID CPR I O A See 8 1 5 Connections of the extension IO Board ID CPR I O A Optionally an internal relay on the ID CPR50 10 RE can be used X3 Signal Description ID CPR50 10 E Descriptio...

Page 31: ...ation ID CPR50 10 E RE FEIG ELECTRONIC GmbH Page 31 of 39 M90701 1de ID B FCC doc E N G L I S H 8 1 3 Connection with PoE Supply PoE Power Supply IEEE802 3af Ethernet Ethernet ID CPR IO ID CPR50 10 E...

Page 32: ...10 E Door Contact X3 4 3 5 6 1 2 NOTICE Use only regulated power supply s Reversing the polarity of the supply voltage may destroy the device Supply voltages outside the specifications may destroy the...

Page 33: ...n Symbol Description Connected with Pin x on X3 CPR50 10 E 1 GND Ground 6 GND D 2 VCC 5 VDC 5 VCC 3 RxD Receive Input 4 OUT 4 TxD Transmit Output 3 IN 5 IN1 Digital Input 1 6 IN2 Digital Input 2 7 Rel...

Page 34: ...is established via a enciphered serial interface The communication connection to the reader ID CPR50 10 E can be realized via the connection RxD Pin3 and TxD Pin4 Fig 9 Communication connection to the...

Page 35: ...een reader and transponder 8 2 1 EMC effects on cables In spite of the internal EMC filters inside the reader high levels of noise on the supply voltage can result in impairment of the communication b...

Page 36: ...0 mm Operating frequency 13 56 MHz RF Transmitting Power 250 mW 2 dB RF Interface ISO14443 A ISO14443 B NFC 2 ISO15693 Supported Transponder e g mifare classic mini 1k 4k mifare UltraLight mifare DESf...

Page 37: ...sly approved by the party responsible for compliance could void the user s authority to operate this equipment NOTE This equipment has been tested and found to comply with the limits for a Class B dig...

Page 38: ...following two conditions 1 this device may not cause interference and 2 this device must accept any interference including inter ference that may cause undesired operation of the device Usually this i...

Page 39: ...1 1de ID B FCC doc E N G L I S H 9 5 Dimensions X1 1 84 2 mm 84 2 mm 60 0 mm 60 0 mm 77 7 mm 56 8 mm 60 0 mm 28 4 mm 28 4 mm 77 7 mm Fig 11 Concealed casing Fixing dimensions Fig 12 Surface adapter di...