OBID
®
classic-pro
Installation
ID CPR50.10-E/-RE
FEIG ELECTRONIC GmbH
Page 27 of 39
M90701-1de-ID-B-FCC.doc
E N G L I S H
8. Installation
The Reader has been designed for wall installation on 60 mm flush-mounting box. For surface in-
stallation you can use the surface adapter.
NOTES:
•
The Reader must not be installed directly upon conductive materials as e.g. metal sur-
faces, metal grids (reinforcements) or metallized surfaces, as these surfaces reduce the
detection range of the Reader.
•
If the reader is installed in a metal frame it must be ensured that a minimum distance of
25mm to the reader is observed.
•
Closed metal frame loop must be interrupted on one position.
If an installation to a metal surface becomes necessary, the surface adapter can be em-
ployed in order to keep the minimal distance.
•
The distance between two Readers of the same type should not fall below 30 cm.
•
Before any installation the intended position of the Reader should be tested for its suit-
ability.
X1
1
Fig. 2 Surface adapter,
Mounting direction,
(
⇑
TOP) on top position
Fig. 3 Concealed casing,
Mounting direction,
(
⇑
TOP) on top position