5.3 Device address (Online-systems)
For readers with RS232 interface usually an address setting isn’t necessary. For devices with
RS485 interface, the device address can be set via the DIP-switch or the host.
Bus mode with up to 16 readers:
Setting the device address is performed via the DIP-switches at athe opened device
(see
Fig. 1: Position of the connecting terminals and the operational control
) according to
the table seen below. by means of this, each reader is provided with an individual
address.
address
DIP 1
DIP 2
DIP 3
DIP 4
0
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
Bus mode with more than 16 readers:
The assignment of addresses is performed via the host.
NOTE:
As all devices are set with the address 0 (factory adjustment), they have to be
connected and configured one after the other.