1. Safety instructions

The device has to be used only for the purpose designed by the manufacturer.

The operation manual has to be stored available at any time and has to be handed over

to each user.

Unauthorized changes and the use of spare parts and additional devices which have not

been sold or recommended by the manufacturer may cause fire, electric shocks or

injuries. Such measures will lead to exclusion of any liability by the manufacturer.

The liability-prescriptions of the manufacturer in the issue valid at the time of purchase

are valid for the device. The manufacturer is not legally responsible for incorrect,

unsuitable manual or automatical setting of parameters for a device or the incorrect

application of a device.

Repairs can only be executed by the manufacturer.

Installation-, operation- and maintenance procedures should only be carried out by

qualified personnel.

Before opening the device, the power supply must always be interrupted. Make sure

that the device is without voltage by measuring. CAUTION! The fading of an operation

control (LED) is no indicator for an interrupted power supply or the device being

without voltage!

Works at the device and its installation have to be executed according to the national

legal requirements and local prescriptions.

When working on devices the valid safety regulations must be observed.

Summary of Contents for ID RW02.ABC-A:ID RW02.ABC-B

Page 1: ...OBID Installation ID RW02 ABC FEIG ELECTRONIC GmbH Page 1 of 18 E N G L I S H ID RW02 ABC A RS232 Interface ID RW02 ABC B RS485 Interface english...

Page 2: ...C TRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information Since desp...

Page 3: ...witches 9 3 2 Power supply 10 3 3 Relay 10 3 4 Digital inputs IN1 IN2 10 3 5 RS232 Interface ID RW02 ABC A 10 3 6 F RS485 Interface ID RW02 ABC B 11 3 7 F Data Clock interface 12 4 Operation 13 4 1 Ad...

Page 4: ...urchase are valid for the device The manufacturer is not legally responsible for incorrect unsuitable manual or automatical setting of parameters for a device or the incorrect application of a device...

Page 5: ...faces metal grids reinforcements or metallized surfaces as these surfaces reduce the detection range of the Reader The distance between the Reader and such surfaces should be min 3 cm If an installat...

Page 6: ...s to be inserted carefully into the socket board X3 see chapter Installation 4 Wallinstallation The wall installation should be executed only after a control of all functions Remove top of the casing...

Page 7: ...oard 1 out of the bottom part of the concealed casing and snap it into the bottom part of casing according to Fig 3 with the connectors in downward direction In order to do this press the notches slig...

Page 8: ...of the casing Fig 4 Connection board connector function board name ID RW02 ABC A ID RW02 ABC B power supply 12 24 AC DC CLS data clock interface cls COM NO relay GND internal GND R A RS232 RxD RS485...

Page 9: ...W02 ABC The jumpers and switches are only accessible at opened device 1 2 3 4 5 6 7 8 ON OFF 1 2 3 X2 X3 X4 J1 J2 S1 X1 X7 1 Fig 5 Jumper and switsches S1 DIP switch to configure the Reader address X1...

Page 10: ...res 3 3 Relay The device is equipped with an relay normally open contact The connection is executed via the connectors NO and COM 3 4 Digital inputs IN1 IN2 The digital inputs IN1 and IN2 can only be...

Page 11: ...ig 5 To operate the bus you need a host computer with a terminating resistor and active termination A twisted paired or stranded wire is recommended Host without termination R A T B ID RW02 with activ...

Page 12: ...L I S H 3 7 F Data Clock interface The connection of the data clock interface is executed according to Fig 11 If no CLS signal is required on host this connection can be abandon Fig 11 connection of t...

Page 13: ...a the DIP switches S1 DIP1 DIP 4 according to the table seen below DIP5 DIP8 are unused Thus each Reader is being provided with an individual address Address DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF...

Page 14: ...al transmitter 1 x bicolor LED red green orange 1 x buzzer relay 1 x normally open capacity of contacts 24 V AC DC 1 5 A digital inputs 2 x configurable length of lead in wire max 3 m interfaces async...

Page 15: ...not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CAUTION Any changes or modifications not expressly appr...

Page 16: ...OBID Installation ID RW02 ABC Page 16 of 18 FEIG ELECTRONIC GmbH E N G L I S H 5 3 Dimensions for concealed installation Fig 12 Dimensions of concealed casing A below...

Page 17: ...ID Installation ID RW02 ABC FEIG ELECTRONIC GmbH Page 17 of 18 E N G L I S H 5 4 Dimensions for surface installation with ID APR A Fig 13 Dimensions for installation with surface frame ID APR A A belo...

Page 18: ...Reader electronic 1 x connection board 1 x adhesive label 1 x thread cutting screw 3 2 x 25 mm for connecting parts of casing 2 x thread cutting screws 3 2 x 15 mm for wall installation 1 x Installat...

Reviews: