background image

OBID

®

Installation

ID RW02.ABC

Page 2 of 18

FEIG ELECTRONIC GmbH

E

N

G

L

I

S

H

Note

Copyright 1999 - 2002 by

FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg-Waldhausen
Tel.: +49 6471 3109-0

http://www.feig.de

With the edition of this document, all previous editions become void. Indications made in this manual may be

changed without previous notice.

Copying of this document, and giving it to others and the use or communication of the contents thereof are

forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved

in the event of the grant of a patent or the registration of a utility model or design.

Composition of the information in this document has been done to the best of our knowledge. FEIG ELEC-

TRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual

and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all

our efforts, errors may not be completely avoided, we are always grateful for your useful advises.

The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC

GmbH does not give any guarantee promise for perfect function in cross environments.

FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this

document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH

does not convey any license under its patent rights nor the rights of others.

OBID

® is registered trademark of FEIG ELECTRONIC GmbH.

General information's regarding this document

The sign "

F

" indicates extensions or changes of this manual compared with the former issue.

Summary of Contents for ID RW02.ABC-A:ID RW02.ABC-B

Page 1: ...OBID Installation ID RW02 ABC FEIG ELECTRONIC GmbH Page 1 of 18 E N G L I S H ID RW02 ABC A RS232 Interface ID RW02 ABC B RS485 Interface english...

Page 2: ...C TRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information Since desp...

Page 3: ...witches 9 3 2 Power supply 10 3 3 Relay 10 3 4 Digital inputs IN1 IN2 10 3 5 RS232 Interface ID RW02 ABC A 10 3 6 F RS485 Interface ID RW02 ABC B 11 3 7 F Data Clock interface 12 4 Operation 13 4 1 Ad...

Page 4: ...urchase are valid for the device The manufacturer is not legally responsible for incorrect unsuitable manual or automatical setting of parameters for a device or the incorrect application of a device...

Page 5: ...faces metal grids reinforcements or metallized surfaces as these surfaces reduce the detection range of the Reader The distance between the Reader and such surfaces should be min 3 cm If an installat...

Page 6: ...s to be inserted carefully into the socket board X3 see chapter Installation 4 Wallinstallation The wall installation should be executed only after a control of all functions Remove top of the casing...

Page 7: ...oard 1 out of the bottom part of the concealed casing and snap it into the bottom part of casing according to Fig 3 with the connectors in downward direction In order to do this press the notches slig...

Page 8: ...of the casing Fig 4 Connection board connector function board name ID RW02 ABC A ID RW02 ABC B power supply 12 24 AC DC CLS data clock interface cls COM NO relay GND internal GND R A RS232 RxD RS485...

Page 9: ...W02 ABC The jumpers and switches are only accessible at opened device 1 2 3 4 5 6 7 8 ON OFF 1 2 3 X2 X3 X4 J1 J2 S1 X1 X7 1 Fig 5 Jumper and switsches S1 DIP switch to configure the Reader address X1...

Page 10: ...res 3 3 Relay The device is equipped with an relay normally open contact The connection is executed via the connectors NO and COM 3 4 Digital inputs IN1 IN2 The digital inputs IN1 and IN2 can only be...

Page 11: ...ig 5 To operate the bus you need a host computer with a terminating resistor and active termination A twisted paired or stranded wire is recommended Host without termination R A T B ID RW02 with activ...

Page 12: ...L I S H 3 7 F Data Clock interface The connection of the data clock interface is executed according to Fig 11 If no CLS signal is required on host this connection can be abandon Fig 11 connection of t...

Page 13: ...a the DIP switches S1 DIP1 DIP 4 according to the table seen below DIP5 DIP8 are unused Thus each Reader is being provided with an individual address Address DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF...

Page 14: ...al transmitter 1 x bicolor LED red green orange 1 x buzzer relay 1 x normally open capacity of contacts 24 V AC DC 1 5 A digital inputs 2 x configurable length of lead in wire max 3 m interfaces async...

Page 15: ...not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CAUTION Any changes or modifications not expressly appr...

Page 16: ...OBID Installation ID RW02 ABC Page 16 of 18 FEIG ELECTRONIC GmbH E N G L I S H 5 3 Dimensions for concealed installation Fig 12 Dimensions of concealed casing A below...

Page 17: ...ID Installation ID RW02 ABC FEIG ELECTRONIC GmbH Page 17 of 18 E N G L I S H 5 4 Dimensions for surface installation with ID APR A Fig 13 Dimensions for installation with surface frame ID APR A A belo...

Page 18: ...Reader electronic 1 x connection board 1 x adhesive label 1 x thread cutting screw 3 2 x 25 mm for connecting parts of casing 2 x thread cutting screws 3 2 x 15 mm for wall installation 1 x Installat...