IDENTIFICATION
ID MAX.U500i
5 Terminals
Page 18 of 36
CAUTION:
•
The outputs are designed for an input voltage of 12-24 V DC and an input current of max. 20 mA.
•
Polarity reversal or overload of the outputs leads to their destruction!
•
The output is only intended for switching resistive loads.
5.5 Relay Outputs on Connector X4
There are 2 relay outputs available at terminal X4 as normally open contacts. Each output is linked fixed with
an antenna. Reading of a valid transponder on the internal antenna will affect the relay REL1, a valid reading
on the external antenna will affect the relay REL2.
Pin Number at
Connector X4
Pin Assignment
5
REL2-COM
6
REL2-NO
7
REL1-COM
8
REL1-NO
Table 8: Pin Assignment Relay Outputs REL1/REL2
Fig. 12: Connector X4 pin assignment for relay outputs
Fig. 13: External wiring of the relay outputs