7.6. CFG12: Read Mode - Filter
Byte
0
1
2
3
4
5
6
0x00
VALID-TIME
1
0x00
0x00
0x00
0x00
0x00
Default
0x0037
5,5sec.
0x00
0x00
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
SCAN-
BREAK-TIME
Default
0x00
0x0001
VALID-TIME:
(0...65535 x 100 ms = 0 ms ... 6553,5 sec)
(OperatingMode.ScanMode.Filter.TransponderValidTime)
The VALID-TIME defines the period in which the Reader does not transmit the Tran-
sponder data a second time, after it has transmitted it the first time (regardless whether
the Transponder is in the detection range of the reader during VALID-TIME or not). The
VALID-TIME starts after the data transmission from the Transponder to the Reader.
Transponder in field
VALID-TIME
Data output
t
r
:
Time to read the Transponder data
t
o
:
Data Transmission from the Reader to the host
t
s
:
VALID-TIME
As long as the VALID-TIME is active, the Transponder can be in the detection
range of the reader or outside of it.
NOTE:
Changing of VALID-TIME only becomes effective after writing configuration block CFG12 to
EEPROM.
start of read
t
r
t
r
t
o
t
s
t
o
t
s