![Feig Electronic ID ISC.MU02.02-CU Manual Download Page 35](http://html1.mh-extra.com/html/feig-electronic/id-isc-mu02-02-cu/id-isc-mu02-02-cu_manual_3882212035.webp)
OBID
i-scan
®
UHF
Manual
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 35 of 96
H90701-3e-ID-B
NOTE:
The internal system timer is not a real time clock (RTC) and the accuracy cannot be guaran-
teed.
If Scan-Mode via data-/clock interface is selected the reader can only transmit the UID or a
Data Block. If both options are activated the reader only transmits the UID. If Scan-Mode via
asynchronous interface is selected reading of UID and Data-Block can be configured at the
same time.
TR-DATA-2:
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
Exten-
sion
-
-
-
-
-
-
Extension
If this flag is set TR-DATA-3 is present
TR-DATA-3:
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
-
-
COM
Prefix
COM Prefix: (OperatingMode.ScanMode.DataFormat.BusAddressPrefix)
b0:
no COM Prefix is send
b1:
The Reader will transmit the COM-ADR before each data set.