DATA-SETS:
Number of Transponder data sets to be transferred in this Reader response.
FLAGS:
Is a bit field and defines which data will be send.
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
ANT
-
-
-
IDD
IDD:
b0
no IDD will be send
b1
IDD will be send
ANT:
b0
no antenna informations will be send
b1
antenna informations (ANT_CNT, ANT_NR, ANT_STATUS, RSSI) will
be send
TR-TYPE:
ANNEX A: Codes of Transponder Types
IDDT:
(Identifier Data Type)
Defines the type of Data transmit beginning at Byte 10. Possible Inventory Data Type See:
ANNEX B: Codes of Identifier Data Types
IDD-LEN:
Identifier Data Length defines the length of the IDD in Byte.
IDD:
Identifier Data of the Transponder
ANT_CNT:
Number of antennas where transponder was read
ANT_NR:
Number of the antenna (1...255)
NOTE:
This command supports all Transponders.
If the STATUS byte of the protocol frame has the value 0x94 more IDD can be read out of the
Reader with MORE = b1.