OBID
i-scan
®
UHF
Manual
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 23 of 96
H90701-3e-ID-B
7.2. CFG1: Interface and Mode
The parameters of the CFG1 configuration block contain the data communication settings.
Byte
0
1
2
3
4
5
6
Contents
COM-ADR
0x00
BAUD
TRANS-
FORM
1
0x00
0x00
TR-
RESPONSE-
TIME
Default
0x00
0x08
0x01
0x00
0x00
38400 Baud
e,8,1
Byte
7
8
9
10
11
12
13
Contents
TR-
RESPONSE-
TIME
0x00
0x02
0x00
SCAN-
INTERFACE
INTERFACE
READER -
MODE
Default
0xF0
0x00
0x11
0x00
1,2 sec.
COM-ADR: (HostInterface.Serial.BusAddress)
Bus address of the Reader (0 .. 254) for communication via the asynchronous interface.
NOTE:
Do not configure address 255!
Via the COM-ADR 255 in the send protocol, the Reader is able to be addressed at any time.
It answers then with the configured address.
BAUD
1
: (HostInterface.Serial.Baudrate)
By means of this byte the baud rate of the asynchronous interface can be defined.
0x05:
4800 baud
0x06:
9600 baud
0x07:
19200 baud
0x08:
38400 baud
0x09:
57600 baud
0x0A:
115200 baud
0x0B:
230400 baud
NOTE:
Changing of BAUD only becomes effective after writing / saving configuration block CFG1
to EEPROM and a reset of the Reader.
The Reader sets the baud rate to 38400 baud, if the user sets an invalid baudrate.
1
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = 0x11.