4.4 Digital Inputs on connector X5
The optocouplers on Terminal X5 are galvanically isolated from the Reader electronics and must
therefore be externally supplied.
Fig. 13: Optocoupler pin-outs IN1
– IN5
Fig. 14: Internal and possible external wiring of the optocoupler inputs
Optocoupler input (X5 / IN1-5):
The input LED associated with the optocoupler is connected internally to a series resistor of 500
Ω
.
For supply voltages of greater than 10V the input current must be limited to max. 20 mA by means
of an additional series resistor (see Table 11)