UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 92 of 117
H71011-0e-ID-B.docx
9.9. [0xA0] Reader-Login
The Reader-Login must be executed after every power up or
9.1. [0x63] RF Controller Reset
command,
if an access to the configuration parameters is desired.
Host
Reader:
Byte
1
2
3
4
5
6 .. 9
10 .. 11
Contents
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0xA0]
READER-ID
CRC16
Host
Reader
Byte
1
2
3
4
5
6
7 .. 8
Contents
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0xA0]
STATUS
23
CRC16
READER-ID:
The READER-ID is a password which protects the configuration parameters from any
read and write access.
The READER-ID can be changed in the configuration block
NOTE:
A Reader-Login with wrong READER-ID causes a "Logout".
A "Logout" can be affected via the command
9.1. [0x63] RF Controller Reset
23