6  Operating and Display Elements 

 

 

Installation 

Page 26 of 35 

 

 

6  Operating and Display Elements 

Operating and Display Elements 

 

6.1  Status LEDs 

 

The status LEDs are located under the push button T1 and the DIP switches S1. 

Reader status LEDs 

Res. 

(yellow)

 

Warning 

(red) 

COM 

(yellow) 

RUN 

(green) 

Description 

FLASH 

While T1 is pushed and hold for 5 s to initiate a reset. 

ON 

Reader performs a reset (after pushing T1 for 5 s). 

FLASH 

Reader operates normally. 

FLASH 

FLASH 

Reader receives a valid protocol from host. 

ON 

FLASH 

RF Warning [0x84] 

FLASH 

(alternating) 

FLASH 

(alternating) 

Hardware warning; perform Reader Diagnostic [0x6E] 
for further information. 

FLASH 

FLASH 

FLASH 

Firmware transfer from host to reader. 
Do not switch off the reader or disconnect the interface 
cable during firmware transfer! 

(sequentially) 

 

Table 12: Reader status LED overview 

Antenna status LEDs 

LED Label 

Color 

Description 

Ext. Ant. 

green 

UHF power switched on 

blue 

transponder detected 

red 

antenna impedance error (unequal 50 

Ω

Int. Ant. 

green 

UHF power switched on 

blue 

transponder detected 

red 

antenna impedance error (unequal 50 

Ω

 

Table 13: Antenna status LED overview 

 

6.2  Push Button T1 

 

By means of the push button T1 a complete configuration reset can be performed. The push button is 
located between the DIP switches and connector X1 on the circuit board. Fig. X shows the position of the 
push button. To press the reset button T1 it is necessary to open the housing by means of the hinge after 
loosening the screws. 
To reset the reader back to factory default push the button for at least 5 s until the reset LED below the 
button is switched on continuously. After releasing the push button the reader performs a restart. 
During a complete configuration reset all parameters of the reader will be reset back to factory default and 
need to be configured again. 

 

 

 

Summary of Contents for 5117.000.00

Page 1: ...IDENTIFICATION M81210 2e ID B INSTALLATION ID LRU500i BD ID LRU500i PoE EU 5117 000 00 5117 001 00 FCC 5117 000 10 5117 001 10 ...

Page 2: ...may not be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guarantee for the functionality of the complete system which incorporates the subject of this document FEIG ELECTRONIC G...

Page 3: ... 5 2 2 Power Supply via PoE Power over Ethernet 15 5 3 Ethernet Interface on Connector X1 16 5 4 RS485 Interface on Connector X3 17 5 5 Data Clock Interface on Connector X3 18 5 6 Digital Outputs on Connector X4 19 5 7 Relay Outputs on Connector X4 20 5 8 Digital Inputs on Connector X5 21 5 9 USB Mini Interface on Connector X6 23 5 9 1 USB Flash Drive Service Functions 23 5 9 2 Reading of Log and ...

Page 4: ...eader Power Adjustment 27 7 Technical Data 28 8 Radio Approvals 30 8 1 Europe CE 30 8 2 USA FCC and Canada IC 31 8 2 1 USA FCC and Canada IC Warning Notices 31 8 2 2 Installation with FCC IC Approval 31 8 2 3 Label Information 32 8 2 4 Antennas Approved in the USA FCC and Canada IC 32 Annex A Accessories 33 List of Tables 34 List of Figures 35 ...

Page 5: ...le for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation operation and maintenance procedures should only be carried out by qualified personnel Use of the device and its installation must be in accordance with national legal requirements and local elec...

Page 6: ...be easily integrated into existing access control systems via the Wiegand or RS485 interface A version with Power over Ethernet PoE and USB is also available To install the compact reader one cable is required for each interface and power supply for PoE only the network cable is required 2 2 Available Reader Types The following readers are available Order Number Reader Type Description 5117 001 00...

Page 7: ...sealing insert for 3 cables cable 2 5 4 5 mm 2 x ID CTF U UHF Windshield Transponder 3 2 ID LRU500i PoE The scope of delivery includes following components 1 x ID LRU500i PoE 1 x MFD 25 01 065 M25 multiple sealing insert for 1 cable cable 4 6 5 mm 1 x ESKV 20 M20 cable gland for cable 6 13 mm for USB 1 x RDE 20 M20 reduction sealing insert for cable 4 8 mm 1 x MFD 20 02 040 M20 multiple sealing in...

Page 8: ...t The screws used should have a screw in depth of maximum 8 mm The housing can be opened by means of a hinge Therefore loosen the screws marked blue in Fig 1 and swing away the front part of the reader During installation the dimensions of the reader when opened should be taken into account see Fig 3 For secondary protection the reader should be secured by means of an eye bolt see Fig 4 that shoul...

Page 9: ...IDENTIFICATION ID LRU500i 4 Installation Installation Page 9 of 35 Fig 2 Dimensional drawing side view ...

Page 10: ...IDENTIFICATION ID LRU500i 4 Installation Installation Page 10 of 35 Fig 3 Dimensional drawing top view opened housing ...

Page 11: ...ID LRU500i 4 Installation Installation Page 11 of 35 NOTE FEIG ELECTRONIC GmbH strongly recommends to secure the reader against falling by means of an eye bolt to prevent damage Fig 4 Secondary protection via eye bolt ...

Page 12: ...ailable operating and display elements Fig 5 Connection Overview Connector Description X1 10 100 Base T Ethernet with RJ45 X2 Power Supply 12 24 V DC 1 0 X3 RS485 Data Clock Wiegand X4 Relay Outputs Digital Outputs X5 Digital Inputs X6 USB Mini Interface Table 1 Connection Terminals Operating Display Element Description T1 Push Button for configuration reset S1 DIP switches to set pre configured o...

Page 13: ...ssible to apply the VCC voltage of the reader 24 V DC max 500 mA directly to the antenna cable The antenna port must be configured accordingly in the reader This option is not possible when powering the reader via PoE Fig 6 External antenna connection CAUTION Exceeding the tightening torque will destroy the antenna connection The activation of the supply voltage on the antenna cable can damage the...

Page 14: ...ower supply according EN 62368 1 Chapter Q 1 or with a NEC Class 2 LPS certified power supply Each reader has to be supplied by a separate external power supply Reversing the polarity of the supply voltage on X2 may destroy the device External wiring for the power supply must fulfil the following norms validation procedures Conductor Cross Section Validation Procedure from 0 5 mm or bigger IEC 603...

Page 15: ...uctor Cross Section CAT5 7 Max Cable Length for PoE 0 4 mm 30 m 0 6 mm 70 m Table 5 Max cable length depending on the conductor cross section For detailed technical information regarding the 802 3at standard please refer to the most recent edition of the corresponding IEEE specification NOTE This functionality is only available with the reader model ID LRU500i PoE It must be ensured that the reade...

Page 16: ... should be used This ensures a reliable operation at 10 Mbps or 100 Mbps The prerequisite for using TCP IP protocol is that each device has a unique IP address on the network All readers have a factory set IP address The transmission parameters can be configured as required Network Address IP Address 192 168 10 10 Subnet Mask 255 255 0 0 Port 10001 DHCP OFF Table 6 Standard factory configuration o...

Page 17: ...e is connected on X3 The transmission parameters can be configured via software protocol Pin Number at Connector X3 Pin Assignment 4 RS485 B 5 RS485 A 6 GND Table 7 Pin Assignment X3 RS485 Interface NOTE The RS485 interface is only available in the reader version ID LRU500i BD Fig 10 RS485 interface pin assignment on X3 ...

Page 18: ... Clock Wiegand Interface NOTE The data clock interface is only available in Scan Mode in the reader version ID LRU500i BD The data clock Wiegand interface cannot be used to configure the reader For access control applications it is possible to connect the reader to two inputs of a Wiegand controller in parallel via an ID ISC LR WS A Wiegand Switch and thus monitor two lanes e g entrance and exit s...

Page 19: ... additional circuitry The output must therefore be supplied with an external voltage Each output is linked fixed with an antenna Reading of a valid transponder on the internal antenna will affect the digital output OPTO1 OUT a valid reading on the external antenna will affect the digital output OPTO2 OUT Pin Number at Connector X4 Pin Assignment 1 OPTO2 OUT C 2 OPTO2 OUT E 3 OPTO1 OUT C 4 OPTO1 OU...

Page 20: ...relay outputs type LRU500i BD only 1 available at terminal X4 as normally open contacts With the LRU500i PoE each output is fixed with an antenna Reading a valid transponder on the internal antenna affects the relay REL1 reading a valid transponder on the external antenna affects the relay REL2 Pin Number at Connector X4 Pin Assignment 5 REL2 COM 6 REL2 NO 7 REL1 COM 8 REL1 NO Table 10 Pin Assignm...

Page 21: ... only In case an inductive load is connected the relay contacts must be protected by an external protective circuit 5 8 Digital Inputs on Connector X5 There are 2 digital inputs available on X5 The optocouplers on X5 are galvanically isolated from the reader electronics and must therefore be supplied with an external voltage Fig 17 Connector X5 pin assignment for digital inputs Fig 16 Connector X4...

Page 22: ...in Assignment X5 digital inputs The external resistor Rext is optional When wiring the reader make sure that the input voltage is at least 10 5 V CAUTION The inputs are designed for an input voltage of 12 24 V DC and an input current of max 20 mA Polarity reversal or overload of the inputs leads to their destruction Fig 18 External wiring of the digital inputs ...

Page 23: ...a an optionally available USB On The Go adapter cable the interface can be converted to a USB host interface The adapter cable allows the connection of a USB memory stick to the reader The USB memory stick can be used to carry out various service functions such as reading log and service data and uploading a configuration file 5 9 2 Reading of Log and Service Data When connecting the USB flash dri...

Page 24: ...nfig Cloning on page 24 In addition the same file will be stored in a subdirectory named after the according device ID see label on the back side of the reader Thereby it is possible to save the configuration files of several readers e g from one system installation to the same USB flash drive All non locked configuration pages CFG pages including the interface parameters of a device will be copie...

Page 25: ...missible range After successful completion of the USB actions the red status LED will go out and the green status LED will start flashing again After the red status LED went out the USB flash drive can be disconnected In case of an error the red status LED will start flashing until the USB flash drive is removed NOTE Connecting a USB flash drive during a running operation of the reader may overwri...

Page 26: ...ble 12 Reader status LED overview Antenna status LEDs LED Label Color Description Ext Ant green UHF power switched on blue transponder detected red antenna impedance error unequal 50 Ω Int Ant green UHF power switched on blue transponder detected red antenna impedance error unequal 50 Ω Table 13 Antenna status LED overview 6 2 Push Button T1 By means of the push button T1 a complete configuration ...

Page 27: ...sonnel of events during maintenance and service 6 5 Reader Power Adjustment In order to achieve high reading ranges it is necessary to set the reader output power to the highest allowed level This depends on the reader type used EU FCC and the applicable radio regulations at the installation site The output power is adjustable in 100 mW steps from 0 1 W to 1 W NOTE Both in the EU version and in th...

Page 28: ...enna SWR control Internal Overheating Protection Outputs 2 x Optocoupler 2 x Relay LRU500i BD 1 x Relay max 24 V DC 20 mA max 24 V DC 1 A switching current 2 A permanent current Inputs 2 x Optocoupler max 24 V DC 20 mA CAUTION Overheating of the device may result in performance losses It is recommended to activate the RF of the reader only if there is a transponder in the detection range of an ant...

Page 29: ...ig Cloning Function Environmental Conditions Temperature Range Operation Storage 25 C to 55 C 25 C to 85 C Humidity 5 to 95 non condensing Vibration EN 60068 2 6 10 Hz to 150 Hz 0 075 mm 1 g Shock EN 60068 2 27 Acceleration 30 g Applicable Standards Radio Regulation Europe USA Canada India EN 302 208 FCC 47 CFR Part 15 IC RSS GEN RSS 210 BIS IS 13252 Part 1 EMC EN 301 489 Safety Low Voltage Human ...

Page 30: ...CTRONIC GmbH declares that the radio equipment type ID LRU500i is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address http www feig de en downloads support declarations of conformity html Performance Classification according to ETSI EN 301 489 Class 2 ...

Page 31: ... will be required to correct the interference at his own expense L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage 2 l appareil doit accepter ...

Page 32: ...gorie I a été approuvé par Industrie Canada pour fonctionner avec les types d antenne énoncé ci dessus et ayant un gain admissible maximal et l impédance requise pour chaque type d antenne Les types d antenne non inclus dans cette liste ou dont le gain est supérieur au gain maximal indiqué sont strictement interdits pour l exploitation de l émetteur Les antennes utilisées pour cet émetteur doit êt...

Page 33: ...Length 2 m 5243 002 00 ID ANT C6 C UHF Antenna Cable R TNC TNC 6 m H155 Coaxial cable for UHF antennas with TNC socket and UHF reader with R TNC connector Connection type Connector R TNC Connector TNC Length 6 m 5335 000 00 ID ANT C6 x UHF Antenna Extension Cable TNC TNC 6 m H155 Coaxial extension cable for UHF antennas with TNC socket Connection type TNC female TNC male Length ca 6 m EU 5236 000 ...

Page 34: ...le length depending on the conductor cross section 15 Table 6 Standard factory configuration of the Ethernet connection 16 Table 7 Pin Assignment X3 RS485 Interface 17 Table 8 Pin Assignment Data Clock Wiegand Interface 18 Table 9 Pin Assignment X4 Digital Outputs 19 Table 10 Pin Assignment Relay Outputs REL1 REL2 20 Table 11 Pin Assignment X5 digital inputs 22 Table 12 Reader status LED overview ...

Page 35: ...rnet connector 16 Fig 10 RS485 interface pin assignment on X3 17 Fig 11 Pin assignment Data Clock Wiegand interface on X3 18 Fig 12 Connector X4 pin assignment for digital outputs 19 Fig 13 internal and external wiring of the digital outputs 19 Fig 14 Connector X4 pin assignment for relay outputs version LRU500i PoE 20 Fig 15 External wiring of the relay outputs 20 Fig 16 Connector X4 pin assignme...

Reviews: