Electric start:
Turn the fuel switch to start position.
Insert the ignition key and turn to “ON” position.
Turn the ignition key to "START" position, do not loosen until the generator is started. Turn the
key no more than 10 seconds. If fail to start, loosen the key and wait 10 seconds to try one more
time.
According to the ambient temperature, push the choke cable inward after the starting the
generator. The lower the ambient temperature is, the slower the inward pushing is. The higher the
ambient temperature is, the faster the inward pushing speed is. Make sure the engine does not
turn off when pushing inwards.
Remote start:
Turn the fuel switch to start position.
Turn the ignition key to "ON" position.
Press TWICE then hold the start button on the remote controller. The generator starts after 1.5
seconds delay. Release the remote control start button after the generator starts. turn the key no
more than 10 seconds. If fail to start, loosen the key and wait 10 seconds to try one more time.
2. When the output indicator lights on the control panel is on, the generator can
be used. Before connecting any load, the generator should be grounded. Please use a thick
cable to the ground terminal on the generator control panel is connected to an external
ground source.
3. Make sure all equipment is turned off and the switch in order to ensure that the equipment is
intact, confirm the use of electrical appliances does not exceed the total power rating of the
generator.
4. Connect your device to a suitable outlet generator control panel.
Turn off Generator
Note
Turn the ignition key to “OFF” position, the generator will stop immediately in any condition.
1. Turn off the generator in the following instructions.
Turn off and unplug the connected equipment.
Turn the ignition key to “OFF” position to stop the generator. Or press the “STOP” button on the
remote controller or the red “STOP” button on the control panel to stop the generator for Remoter
Start model.
Turn off the fuel switch.
When not using the generator for a long time, please turn off the generator.
Foreword
Thank you for purchasing our Inverter generator
This manual includes the operation and maintenance of Model FGHI7000
R
series
inverter
generator. All contents of this manual are consistent with the latest products (when this manual is
printed).
Our company reserves the right to make changes without notice and without any liability.
This manual is owned by BUILDER SAS and is not allowed to be recorded without written
permission. This manual should be considered as a permanent part of the generator and should be
kept with it if the generator is resold.
Please pay special attention to the following text: