Feider Machines FGHI7000R User Manual Download Page 30

WARRANTY

The  manufacturer  guarantees  the  product  against  defects  in  material  and  workmanship  for  a  period  of  2 
years from the date of the original purchase. The warranty only applies if the product is for household use. 
The warranty does not cover breakdowns due to normal wear and tear.

The  manufacturer  agrees  to  replace  parts  identifed  as  defective  by  the  designated  distributor.      The 
manufacturer does not accept responsibility for the replacement of the machine, in whole or in part , and/or 
ensuing damage.

The warranty does not cover breakdowns due to:

• insufcient maintenance.

• abnormal assembly, adjustment or operations of the product.

• parts subject to normal wear and tear.

The warranty does not extend to:

• shipping and packaging costs.

• using the tool for a purpose other than that for which it was designed.

• the use and maintenance of the machine done in a manner not described in the user manual.

Due to our policy of continuous product improvement, we reserve the right to alter or change specifcations 
without  notice.  Consequently,  the  product  may  be  diferent  from  the  information  contained  therein,  but  a 
modifcation  will  be  undertaken  without  notice  if  it  is  recognized  as  an  improvement  of  the  preceding 
characteristic.

READ THE MANUAL CAREFULLY BEFORE USING THE MACHINE.

When ordering spare parts, please indicate the part number or code, you can fnd this in the spare parts list 
in this manual. Keep the purchase receipt; without it, the warranty is invalid. To help you with your product, 
we invite you to contact us by phone or via our website:

• 

+33 (0)9.70.75.30.30

• 

https://services.swap-europe.com/contact

You must create a "ticket" via the web platform.

• Register or create your account.

• Indicate the reference of the tool.

• Choose the subject of your request.

• Describe your problem.

• Attach these fles: invoice or sales receipt, photo 

of the identifcation plate (serial number), photo 
of  the  part  you  need  (for  example:  pins  on  the 
transformer plug which are broken).

1

5

. WARRANTY

30

Summary of Contents for FGHI7000R

Page 1: ...ORIGINAL INSTRUCTIONS EN PETROL INVERTER GENERATOR FGHI7000R USER GUIDE CAUTION Read this manual before using this machine...

Page 2: ...BEFORE OPERATION 10 6 START THE ENGINE 13 7 OPERATING THE GENERATOR 15 8 SHUT OFF THE ENGINE 19 9 MAINTENANCE 20 10 TRANSPORTATION WAREHOUSING 24 11 TROUBLESHOOTING 25 12 SPECIFICATIONS 27 13 CIRCUIT...

Page 3: ...as this can get caught in the machinery as it runs Use safety equipment Wear protective gear such as an anti dust mask non slip safety shoes a helmet or hearing protection Stay vigilant watch what yo...

Page 4: ...ause burns Pay attention to the warnings on the generating set Engine exhaust gases are toxic Do not operate the generating set in unventilated rooms When installed in ventilated rooms additional requ...

Page 5: ...t and that they are used correctly The connection of a generator used for auxiliary power to the electrical installation of a building must be performed by a qualified electrician and in conformity to...

Page 6: ...n Fill in engine oil It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death This symbol indicates the surface is very hot and no...

Page 7: ...eter to see whether the battery is losing electricity Standard voltage 12V 13 5V If the battery voltage is too low please recharge it with the battery charger Charge for 3 hours or until full disconne...

Page 8: ...an external ground source 3 Make sure all equipment is turned off and the switch in order to ensure that the equipment is intact confirm the use of electrical appliances does not exceed the total pow...

Page 9: ...BE CAUTIOUS As long as following the instructions in this manual the generators are safe and reliable Be sure to read and understand the instructions before use otherwise incorrect operation could re...

Page 10: ...EFORE OPERATION The generator should be placed on a flat ground without debris around and at least 1 meter away from buildings and other equipment BE CAUTIOUS Be sure to check whether the generator is...

Page 11: ...e the cover Remove the oil dipstick wipe the dipstick with a clean cloth insert it into the oil port without tightening the dipstick to check the oil level If the oil level is below the bottom of the...

Page 12: ...fuel or oil mist may catch fire If there is a fuel spill make sure that the fuel is evaporated completely before the engine starts Avoid prolonged repeated exposure to gasoline or inhale mist Do not l...

Page 13: ...osen the screw on battery cover and remove the cover Connect the battery cable to the generator start cable Reinstall the battery cover 6 START THE ENGINE NOTICE The engine can be started with three m...

Page 14: ...ghtly to prevent the generator from overturning Electric Start Turn on the fuel switch Turn the key to ON position Turn the ignition key to the START position until the generator is running Hold the k...

Page 15: ...the generator to its power system shall be carried out by a professional electrician and must comply with the applicable laws and regulations Otherwise the power of the generator may impact on the pu...

Page 16: ...in real time If the generator is overloading or the connected device is internally faulty the LCD will display 0 instead of the status of the generator on Voltage Current or Frequency and the Power co...

Page 17: ...tor power should be reduced Ambient temperature coefficient Relative humidity 30 Altitude m Ambient temperature 25 30 35 40 45 0 1 0 98 0 96 0 93 0 90 500 0 93 0 88 0 83 0 78 0 73 1000 0 87 0 82 0 77...

Page 18: ...ld be properly connected to the positive and negative terminals of the battery otherwise it will damage the generator or the battery WARNING Charge should be properly ventilated and away from firework...

Page 19: ...the oil alert indicator red will flash briefly and the engine will no longer operate Please check the oil level regularly 8 SHUT OFF THE ENGINE If you need to shut down the engine urgently turn the k...

Page 20: ...ied month or hour Project Periodic maintenance time 1 Each use Per month or 20 hours Every 3 months or 50 hours Every 6 months or 100 hours Per year or 300 hours Engine oil an examination Replace Air...

Page 21: ...rly Oil capacity 1 1L Wash your hands with soap and water after you touch the oil BE CAUTIOUS In order to comply with environmental requirements we recommend that collect the waste oil into a sealed c...

Page 22: ...er drawer as shown by the arrow below Pull out the air filter drawer check the air filter sponge and if necessary clean or replace the filter Clean or replace the filter and then follow the opposite a...

Page 23: ...park plug with different heat value Maintenance of Muffler Fireproof Net Dirty muffler will affect the effect of the generator and the power of the engine To ensure the normal operation of the generat...

Page 24: ...rough road for a long time If you have to do so please drain the fuel before transporting the generator Before long term storage Make sure the storage area is dry and clean Drain all fuel out WARNING...

Page 25: ...ug will cause burns NOTICE If the generator cannot be started for the first time when the oil is added or the oil is changed the oil alarm indicator flashes when pulling the start handle at this time...

Page 26: ...generator Replace the device Get the device repaired Is DC protector ON Reset the DC protector Return the generator to an authorized dealer for further assistance No Return the generator to an author...

Page 27: ...pressure level LpA 74 7 dB A K 0 93dB A Sound power level LwA 95 7 dB A K 0 93dB A Guaranteed sound power level 96 dB A Generator set AC out put Voltage 230 V AC Frequency 50 Hz AC rated output power...

Page 28: ...13 CIRCUIT DIAGRAM 28...

Page 29: ...ive 2014 30 EC ROHS Directive EU 2015 863 amending 2011 65 EU Emission directive EU 2016 1628 2018 989 EU Noise directive 2000 14 CE Annex VI 2005 88 CE European harmonized standerds including if appl...

Page 30: ...he user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information co...

Page 31: ...pairs will be done by approved engine manufacturers of these manufacturers see their site http www briggsandstratton com eu fr http www honda engines eu com fr service network page jsessionid 5EE8456C...

Page 32: ...sary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair stat...

Page 33: ...BUILDER SAS 32 rue Aristide Berg s Z I du Casque 31270 Cugnaux France MADE IN PRC...

Reviews: