11. TROUBLESHOOTING
Cannot start the engine
有
是
是
Check spark plug:
Remove the ignition coil and clean the dirt around the spark plug.
Remove the spark plug and insert the spark plug into the ignition coil.
Connect the spark plug side electrode with wire to the metal part of the engine to ground. (You
can use the DC output wire to replace the wire. Use one end of the clip to clamp the metal part of
the engine, and the other end connect to the side electrode of the spark plug.)
Pull the start handle, spark should jump from the gap.
NOTICE
Ensure that the engine is cooled down when you check the spark plug, or the high
temperature of the engine and spark plug will cause burns.
NOTICE
If the generator cannot be started for the first time when the oil is added, or the oil is changed,
the oil alarm indicator flashes when pulling the start handle, at this time, the generator should
be shaken back and forth to ensure that the float of the oil alarm floats. If the generator still
does not start, please follow the troubleshooting instruction above.
NOTICE
Make sure no fuel spills around the spark plug. Spilled fuel may catch fire.
Is there any fuel in the tank
?
Is the start switch & fuel switch on?
Does the engine has enough oil
?
Does the spark plug
work
?
Refuel
Turn the switch to “ON” position
Add recommended oil
Replace
Return the generator to
an authorized dealer for
further assistance
Still not
working
否
否
No
Yes
Yes
Yes
No
Does the carburetor has enough
gasoline
?
Check if the tubes are damaged
Yes
否
No
No
No
25