background image

find air leak, release the pressure from the air nozzle and before further use secure a control and 
compressor repair at the authorized service center. 

 

CAUTION!

 

Never use a compressor which has a compressed air leak! 

Move the machine only by lifting the handle, never by pulling hoses and cables attached. 

PREPARATION FOR OPERATION 
WARING! 

Compressor  use,  always  store  and  transport  in  operating  position  (standing  by  supporting  foot  and 
wheels on a level solid surface - tank down and compressor engine up. Compressor never tilt or upside 

down! 

CONNECTING AND DISCONNECTING OF THE AIR HOSE 

The machine is equipped with quick-coupling to connect the air hose. 

 

Use of the compressed air for the various purposes envisaged (inflation, air- powered tools, painting, 

washing  with  water-based  detergents  only,  etc.)  requires  knowledge  of  and  compliance  with  the 
rules established for each individual use. 

 

Always bleed pressure from the tank before attempting maintenance, attaching tools or accessories. 

When  connecting  an  air-powered  tool  to  a  hose  of  compressed  air  supplied  by  the  compressor, 

interruption of the flow of air from the hose is compulsory. 

Interruption of the flow of air from the hose is compulsory. 

CONNECTING OF THE AIR HOSE

 

1.

 

Pull collar back in direction to manometer 

(fig. 5A).

 

2.

 

Push the air hose connector into the socket 

(fig. 5B)

 and release the collar. 

3.

 

Check if the air hose is connected properly. 

DISCONNECTING OF THE AIR HOSE

 

1.

 

Push the air hose connector into the socket. 

2.

 

Pull collar back in direction to manometer. 

3.

 

Pull the air hose connector out and release the collar. 

SETTING OF THE OPERATING PRESSURE

 

Adjusted operating pressure can be read on the manometer 

(fig. 6C).

 

Rotate  with  the  regulator 

(fig.  6A)

  according  to  the  arrows  for  increasing  or  decreasing  of  operating 

pressure  (locking  nut  have  to  be  loosened 

(fig.  6B).

  During  pressure  reducing  is  the  change  on  the 

manometer note only after the partial reduction of air. 
The  setting  can  be  locked  by  red  lock  nut 

(fig.  6B),

  by  adjust  of  needed  pressure  and  the  locking  nut 

unscrew to the knob. After the temporary reduction in pressure, it can be easily to set back the pressure in 
the output needed by turning of the valve to the locking nut. For new pressure adjusting is necessary to 
unscrew the lock nut to the bottom position. If you cannot turn the valve, it is probably too tight to the 
lock nut. 

 

CAUTION! 

Never exceed the maximum operating pressure level of the connected device. Do not tighten the 

lock nut by the excessive force. 

OPERATION 

Please, read carefully the following steps before using of machine: 

Always bleed pressure from the tank before attempting maintenance, attaching tools or accessories.

 

 

Check if are the nuts and bolts tightened well 

Summary of Contents for FC24LS

Page 1: ...nal Instruction manual Oil free compressor Feider France ZI 32 rue Aristide Bergès 31270 Cugnaux France MADE IN RPC 2018 Warning Please read the manual carefully before using this machine FC6LS FC24LS FC50LS ...

Page 2: ...n Risk of electric shock Do not open the valve before connecting the air hose Do not use the machine with open or removed covers Do not move it during operation Danger automatic control Attention Hot surface Prohibition do not start Warning Maintenance work in progress ...

Page 3: ...ection hole G main switch O supporting foot H self propelled handle P pressure relief valve Inspection hole is used for inspection and cleaning of the pressure tank may only be performed by an authorized service centre 3 SPECIFICATIONS Model FC6LS FC24LS FC50LS Rated voltage 220 230V 220 230V 220 230V Rated frequency 50Hz 50Hz 50Hz Motor 4 poles 4 poles 4 poles Input power 0 5 kW 0 8 kW 1 15 kW ...

Page 4: ...C50LS is the basic model 2 other models were designed to same structure with FC50LS except rated power and the volume of tank 3 the assessment of each type of model covers each series of machine of essentially identical design b Input temperature 10 40 intermediate temperature 170 200 c Discharge Temperature 10 40 d Input pressure 0 Bar Intermediate and discharge pressure 0 8Bar e For Air Compress...

Page 5: ......

Page 6: ...SPECIFIC TERMS AND CONDITIONS OF USE This product is exclusively intended for the use for generating compressed air for tools operated by compressed air your new air compressor can be used for operating paint sprayers air tools grease guns airbrushes caulking guns sandblasters inflating tires and plastic toys spraying weed killer and insecticides etc In most of these applications is needed to set ...

Page 7: ...is product Carefully read the instruction manual Learn how to use this product all restrictions and what risks could related with its use Learn the product quickly stop and turn off the controls Be careful at work be concentrated on actual work and use the common sense If the product is not in use it should be stored in a dry and secure place out of the reach of children Never pull the plug from t...

Page 8: ...nozzle leaks showing signs of deep corrosion mechanical damage or escape the air immediately turn off the machine and entrust it to an authorized service center Usingthemachinewith adamaged airnozzlemaylead toruptureoftheairnozzle or theunexpectedleaking of high pressureairandthustoamortalorseriouspersonalinjuryorotherdamage topersonsorproperty ELECTRICALREQUIREMENTS The machine must be plugged in...

Page 9: ...f the product Dangers caused by unexpected starting unexpected exceeding of engine revs caused by defect failure of control system relate to the defects by the handle and placing of drivers Dangers caused by impossibility to stop the product in best conditions relate to solidity of the handle and placing of engine shut down product Dangers caused by defect of product control system relate to solid...

Page 10: ...mbly kit 1x air filter 1x manual for use Standard accessories are subject to change without notice This product requires assembly The product must be assembled correctly before use After unpacking the box check the status of the compressor for signs of damage In particular carefully check the air nozzle Place the compressor on a horizontal flat and firm surface so that the compressor body is direc...

Page 11: ...to manometer fig 5A 2 Push the air hose connector into the socket fig 5B and release the collar 3 Check if the air hose is connected properly DISCONNECTING OF THE AIR HOSE 1 Push the air hose connector into the socket 2 Pull collar back in direction to manometer 3 Pull the air hose connector out and release the collar SETTINGOFTHEOPERATING PRESSURE Adjusted operating pressure can be read on the ma...

Page 12: ...WAYS SWITCH THE ENGINE OFF wait for all moving parts to stop and allow the machine to cool down Prevent the engine from being started accidentally disconnect the power unit from the mains Always bleed pressure from the air hose and tank before attempting maintenance attaching tools or accessories Unplug the tool from the supply mains Never plug and switch off the tool during maintenance Always mak...

Page 13: ...ean the machine after each use Do not let the handles contaminate with oil or grease Clean the handle clean with a damp cloth washed in soapy water Never use aggressive detergents or solvents for cleaning This can cause irreparable damage to the product The plastic parts can be eaten away by chemicals Wipe down the product with a slightly damp cloth or with brush Clean the cover of the machine esp...

Page 14: ...Whether you need technical advice repairs or genuine factory replacement parts contact SWAP Information on service locations visit WWW SWAP EUROPE COM When ordering spare parts please quote the part number this can be found at WWW SWAP EUROPE COM DISPOSAL_______________________________________________________________ Electrical products should not be discarded with household products According to ...

Page 15: ...S Serial number FC6LS FC24LS FC50LS Complies with the provisions of the Directive Machinery 2006 42 EC and national laws transposing it Also complies with the following European directives EMC Directive 2014 30 EU Also complies with European standards with national standards and the following technical provisions EN 1012 2010 EN 61000 6 1 2007 EN 61000 6 3 2007 A1 2011 Cugnaux 12 10 2018 Philippe ...

Reviews: