Modulation source 

    

Under the modulation function, click the “SOUR” button to switch the modulation 

source, that is, select the modulation signal. 

 

      There are four types of sources in FSK, ASK, PSK, and trigger modes: 

  CH2: Use the signal of channel 2 as a modulation signal. 

  External (AC): External signals are AC-coupled through the EXT.IN port. 

  Manual: Use the manual "OK" button as the modulation signal. 

  External (DC): External signal input via TTL_IO port in DC-coupled form. 

 

There are two sources in the AM, FM, and PM modes: 

  CH2: Use the signal of channel 2 as a modulation signal. 

  External (Ext.IN): External signals are connected in DC-coupled form via the EXT.IN 

port. 

 

 

Each time the "Source" button is pressed, the function will switch down once. 

 

 

 

Modulation parameters 

    

Under the modulation function, click the “Parameters” button to adjust the modulation 

parameters. 

      E.g: 

  In the "FSK" mode, the frequency of frequency hopping can be adjusted. 

  In the "trigger" mode, the number of output pulse trains can be adjusted. 

  In the "AM" mode, you can adjust the modulation rate of the amplitude modulation (0 

to 200%). 

  In FM mode, frequency offset parameters can be adjusted. 

  In the "PM" mode, the degree of phase deviation can be adjusted. 

 

 

Other key functions 

Click “FREQ” button under the modulation function to adjust the frequency of CH1. 
Click the “AMPL” button under the modulation function to adjust the amplitude of CH1. 
 

 

 

 

 

 

Summary of Contents for FY6800 Series

Page 1: ...FeelElec FY6800 Series Fully Numerical Control Dual Channel Function Arbitrary Waveform Generator User s Manual Rev1 1 April 2018...

Page 2: ...terial FeelElec shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any...

Page 3: ...ude 19 Set Offset 20 Set Duty Cycle Square 21 Set Phase 22 Enable Output 23 Example Output Sine Waveform 24 Turn on burst function 28 Frequency Meter Counter 29 Enable the Counter 29 Set the Counter 3...

Page 4: ...hortcut keys and graphical user interface simplifies every operation Users do not have to spend a lot of time to learn and familiar with the operation of the instrument you can be skilled use For educ...

Page 5: ...same time Two or more instruments can synchronize multiple instruments through the SYNC port Up to 98 sets of function arbitrary waveforms can be output including 34 sets of preset waveforms and 64 se...

Page 6: ...on types AM FM PM ASK FSK and PSK modulations 100M Frequency meter function It can measure frequency period pulse width and duty cycle Max frequency workable is 100MHz and Min frequency workable is 0...

Page 7: ...ent have been checked for completeness and the instrument has passed both electrical and mechanical tests The consigner or carrier shall be liable for the damage to instrument resulting from shipment...

Page 8: ...n You can switch between sine square wave triangle wave and any type of arbitrary wave Change the selected channel signal type Trigger and modulation function buttons Can set a specific number of puls...

Page 9: ...ase counterclockwise the value at the current cursor 6 Power Button The power indicator will remain on when it is turned on When the signal generator is turned off the indicator light will enter the b...

Page 10: ...ctor outputs the signal in the current configuration Press this button again the indicator light goes off and at this point the CH2 output is turned off 9 CH2 channel output connector BNC connector no...

Page 11: ...and so on Frequency of external signal input should be lower than 500 Hz SYNC OUT Synchronization signal output terminal SYNC IN Synchronization signal input terminal 2 TTL signal output Frequency of...

Page 12: ...n 5W Power On Turn on the power switch after the power cord is connected The generator will execute self inspection The LCD will show welcome interface after the inspection is over If the generator ca...

Page 13: ...1 Current channel selected Display current channel selected for operation 2 Current waveform selected Display the name of current waveform selected For example CH1 Sine means current waveform selected...

Page 14: ...use ADJ Knob and Arrows to change the value 9 Duty Cycle Display Duty Cycle value of current channel Press DUTY button to highlight it and use ADJ Knob and Arrows to change the value 10 Phase Display...

Page 15: ...FY6800 Series User s Manual 15 Appearance and Dimensions...

Page 16: ...e the instrument to output various waveforms Select Output Channel CH1 and CH2 buttons are used to change current channel selected At start up CH1 is displayed on the top with yellow color and CH2 is...

Page 17: ...lf Wave Rectification Negative Half Wave Rectification User defined waveform Press WAVE to change waveform selected Or rotate ADJ Knob under waveform switching status to change waveform The waveform d...

Page 18: ...re different For detailed information please refer to Frequency in Specifications The default frequency is 10kHz Press FREQ button to highlight value of Frequency Then use Arrow buttons and ADJ Knob t...

Page 19: ...nts 1 What s the difference of amplitude in Vpp and the corresponding value in Vrms Answer Vpp is the unit for signal peak peak value and Vrms is the unit for signal effective value The default unit i...

Page 20: ...ADJ Knob to set the value Press Arrows button to move the cursor and rotate ADJ Knob to set the value The offset accuracy is 1mV i e 0 001V When frequency output is lower than 20MHz the offset can be...

Page 21: ...g range of duty cycle is 0 1 99 9 Press ADJ Knob under duty cycle setting status will initial the value to 50 Set pulse wave pulse width Adj Pulse wave Adjustable pulse wave refers to the square wave...

Page 22: ...on is 0 1 The default phase value is 0 The start phase displayed on the screen is the default value or the phase previously set Then press PHAS button to highlight phase value Then use Arrows button a...

Page 23: ...status of dual channels For CH1 there are two status 1 Generator is in parameter setting status and current channel selected is CH1 then press CH1 to switch between output ON OFF 2 Generator is in ot...

Page 24: ...nob to get 2 FREQ 00 020 000 000 000kHz 4 Set the Amplitude Press AMPL to highlight the amplitude value Press Arrow buttons to move the cursor and rotate the ADJ Knob to get the figures below AMPL 02...

Page 25: ...FY6800 Series User s Manual 25...

Page 26: ...ulse train output and AM FM PM analog signal modulation function The modulation signal is input by the Trig FSK ASK PSK IN at the end of the signal generator Modulation parameter setting interface Not...

Page 27: ...l Ext IN External signals are connected in DC coupled form via the EXT IN port Each time the Source button is pressed the function will switch down once Modulation parameters Under the modulation func...

Page 28: ...esponding soft keys Press the corresponding soft key of Parameter to set the number of pulse train pulses When the number of pulses is selected use the arrow keys and parameter adjustment knob to chan...

Page 29: ...upling or Trig IN DC coupling The result will be displayed on the screen in real time The lowest frequency workable is 0 01 Hz GATE TIME 100S Press COUNTER button to enter external pulse counter funct...

Page 30: ...ate time for low frequency signal Gate Time Frequency Resolution 1S 1Hz 10S 0 1Hz 100S 0 01Hz Coupling Set the coupling mode of the input signal to AC or DC and the default is AC When the AC coupling...

Page 31: ...include frequency amplitude offset duty cycle It can be selected by pressing OBJE button In Frequency Sweep Mode the generator will output signal variably from start frequency to end frequency within...

Page 32: ...000 000kHz Amplitude Sweep Press STAR button to highlight start amplitude parameter Press the Arrow buttons and rotate the ADJ Knob to set the specified value For example START 10 00V Offset Sweep Pre...

Page 33: ...00 000 000kHz Amplitude Sweep Press END button to highlight end amplitude parameter Press the Arrow buttons and rotate the ADJ Knob to set the specified value For example END 20 00V Offset Sweep Press...

Page 34: ...al Sweep VCO function It can realize voltage controlling frequency VCF voltage controlling amplitude VCA voltage controlling offset voltage controlling duty cycle and so on Operation method Press VCO...

Page 35: ...alue Start value Sweep time 100 Logarithm Sweep In linear sweep type the signal parameter varies logarithmically For example in the frequency sweep the output frequency changes in the way of octave pe...

Page 36: ...generator sweeps from low frequency to high frequency Start Frequency End Frequency the generator sweeps from high frequency to low frequency Start Frequency Stop Frequency the generator outputs with...

Page 37: ...ent parameters of waveform to save positions 20 sets LOAD To load parameters to current working status from save positions CONF To set system language turn on off Buzzer and Uplink mode MORE To set de...

Page 38: ...d parameters of waveforms previously set to current system status Select S xx on the right to save current parameters to corresponding position Select L xx on the right to load parameters from corresp...

Page 39: ...ress corresponding buttons to select system work mode Press button to select Chinese as system language Press Eng button to select English as system language Press BUZZ button to turn on off buzzer On...

Page 40: ...the UPLINK to be ON Set all other machines to be slave machines Press SYSTEM CONF M S to set the UPLINK MODE to be Slave Press UPLI to set the UPLINK to be ON Repeat this step to set all slave machin...

Page 41: ...ation include waveform frequency amplitude offset and duty cycle which can be set separately The WAVE soft key is highlighted The waveform type of CH2 and the waveform type of CH1 change synchronously...

Page 42: ...ment after finishing the above inspections 4 If it still does not work correctly please contact FeelElec CH2 is locked 1 Check that the signal generator is operating in synchronous state Press the SYS...

Page 43: ...nimum width can reach 20ns Min Resolution on all frequency range 1 Hz Min resolution can reach 1 Hz on all frequency range to ensure adjusting accuracy under high frequency For example it can output 1...

Page 44: ...l channels can work more than 60 seconds when the load is short circuited DC Offset Offset Range Frequency 20MHz 10V Frequency 20MHz 2 5V Offset Resolution 1mV Phase Feature Phase range 0 359 99 Phase...

Page 45: ...signal range to input 0 5V VCO signal frequency range 0 2000Hz VCO control object voltage controlling frequency VCF voltage controlling amplitude VCA voltage controlling offset voltage controlling dut...

Page 46: ...10MHz Burst Function Carrier Waveform Sine Square Ramp Arbitrary except DC Burst Count 1 1048575 Trigger Source Manual Internal External AC DC General Specifications Display Type 2 4 inch TFT Color Di...

Page 47: ...h and all the company managers and employees and auxiliary agents distributors other personnel concerned will be released from any claim including all the costs expenses attorney fees etc that may res...

Reviews: