background image

mr

.

steam

®

 

Electric Towel Warmers

   

Installation and Operating Instructions

________________________________________________________________

 

6

MODELS  W500 

  

TO PREVENT SHOCK HAZARD, BE CERTAIN

THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL BEFORE

ANY WIRING IS DONE.

Box Contents

• Towel Warmer

• (6) Screws

• (1) Upper Threaded Flange

• (1) Lower Wiring Flange

• (1) Small Allen Key

• (1) Large Allen Key

• Instruction & Operation Manual

• Warranty

1. Remove the Towel Warmer and parts from the packing materials.

2. Rotate the upper bracket as shown.

IMPORTANT:

 DO NOT LOOSEN SCREWS TO SWIVEL

BRACKETS. LOOSENING SCREWS WILL CAUSE INTERNAL

LIQUID TO ESCAPE AND CAUSE PRODUCT DAMAGE.

3. Spin on upper threaded flange as shown.
4. Using the smaller allen key provided, loosen the wiring box 

  set screw. DO NOT remove the wiring box.

5. Rotate the wiring box as shown. Tighten the set screw firmly to 

prevent the wiring box from rotating.

6. Place the Towel Warmer in the desired location and mark the 

location of the upper threaded flange and wiring box. Use a level 

to insure proper alignment.

NOTE:

 the Towel Warmer swing range.

7. Mount the lower wiring box per instructions on page 7.

   

If a single gang electric box has been roughed-in, 

then see page 3 for installation instructions.

 

 Install Towel Warmers in upright position only. 

Locate with indicator light on bottom as shown. Failure to install 

properly may result in overheating and a hazardous condition.

Level

 

Upper Support Bracket

Upper Threaded Flange

Wiring

Box

This 

End

Up

!

WARNING

!

WARNING

!

WARNING

Summary of Contents for mr steam Fifth Avenue W500

Page 1: ...Fifth Avenue Collection Electric Hydronic Towel Warmers Models W500 W542 H542 W634 mr steam Feel Good Inc pur 103852 rev 1 15 IMPORTANT NOTE As you follow these instructions you will notice warning an...

Page 2: ...n precautions for your safety 1 INSTALLATION PROCEDURES FOR PERMANENTLY WIRED WALL MOUNTED UNITS MUST BE ACCOMPLISHED BY QUALIFIED PERSONNEL IN STRICT ACCORD WITH APPLICABLE NATIONAL AND LOCAL BUILDIN...

Page 3: ...formation DO NOT install the Towel Warmer without these instructions Cover Plate Part Numbers Decorative Finishes Polished Chrome 103877PC Polished Brass 103877PB Polished Nickel 103877PN Pewter 10387...

Page 4: ...C D W 500 22 5 8 W 542 1 1 8 2 3 4 18 1 2 243 4 W 634 1 1 8 2 3 4 143 16 2611 16 Install Towel Warmers in upright position only Locate with indicator light on bottom as shown Failure to install prope...

Page 5: ...rk the location where the brass inserts will be mounted to hang the towel warmer Before securing the towel warmer to the wall check to ensure the mounting points are level 6 Using the screws provided...

Page 6: ...n on upper threaded flange as shown 4 Using the smaller allen key provided loosen the wiring box set screw DO NOT remove the wiring box 5 Rotate the wiring box as shown Tighten the set screw firmly to...

Page 7: ...tighten the set screw firmly Secure the upper threaded flanges and lower bracket with screws provided ELECTRICAL CONNECTIONS Models W500 W542 W634 TO PREVENT SHOCK HAZARD BE CERTAIN THAT ELECTRICITY...

Page 8: ...upply Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 2 of pur 103852 A Electrical connections should be made as prescribed by the National Electric and Local Codes...

Page 9: ...s properly attached to the wall FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS 3 Do not use an abrasive cleaner on the Towel Warmer A mild detergent will clean and restore most units to their...

Page 10: ...Minimum Header Size 2 x 6 18 5 Inlet Outlet Pipe Center to Center 22 Min Header Length Sliding Escutcheon Set Screw Towel Warmer Header Finished surface of wall Brass Insert Screw STEP 1 PRE INSTALLAT...

Page 11: ...Straight coupling or similar Field Plumbing Escutcheon Washer Valve Union STEP 3 INSTALLATION A Mounting 1 The Mr Steam Towel Warmer has been designed with integral mounting brackets These will facili...

Page 12: ...Turn this union only to assemble the valve to the upright tube 1 2 Pipe field supplied Valve Washer Optional eccentric coupling supplied Do not spin this valve onto the upright tube as this may cause...