Page 2: ...ine No oil is in a new machine Pump will be damaged if it is running without oil Before starting the machine please ensure the oil level in the pump is past the fill line Filling the oil from other positions of pump may damage the pump Only add oil into the pump through the oil port Do not inhale any gas expelling from the pump during operation Doing so can be harmful to your health Always use the...

Page 3: ...d then submerge in cold water to stop the cooking process to kill any enzymes that may cause out gassing when vacuumed IMPORTANT NEVER vacuum pack garlic fungi like mushrooms or soft cheese like Brie Camembert and Ricotta A dangerous chemical reaction takes place when air is removed causing them to be extremely dangerous if ingested FOOD TYPICAL STORAGE VACUUM FRIDGE STORAGE VACUUM FREEZER STORAGE...

Page 4: ...flush option Set to 0 0 seconds 5 Vacuum Light Illuminates when adjusting the vacuum time It also illuminates during the vacuum process 6 LED Display Displays current cycle time in seconds 7 Set Button Press to set the vacuum or sealing time then use the up down arrow buttons to make adjustments 8 Down Up Arrow Buttons Press to decrease increase the vacuum sealing or cooling time 9 Stop Button Pre...

Page 5: ...will damage the pump Keep the machine on a flat level surface Maintain a distance of 4 between the unit and walls or other objects for ventilation Keep the machine away from any heat sources or steaming devices such as fryers ovens dishwashing machines or stoves BE CAUTIOUS Do not damage the machine Please make sure the environment where the machine is being installed conforms to safety regulation...

Page 6: ...reen and be saved to the machine Note For setting the Vacuum time you can use filler plates to occupy space in the chamber leaving less air to be removed from the chamber thus decreasing the overall vacuuming time Note For setting the Sealing time it is recommended you increase the seal time by small increments of 0 1 to avoid over sealing or melting the bag 3 Upon finishing setting the timing con...

Page 7: ...lting The cycle finishes and the lid releases 5 Inspect the pouch to ensure desired vacuum and seal is achieved Vacuum Quality If the quality of vacuum is not adequate or if the pouch is not tight enough inspect the pouch for air pockets or air leaks If no leaks are evident increase the vacuum time by 5 seconds and begin the process again at Step 2 Note Some vegetables may emit out gassing when th...

Page 8: ... use an acetone acetone based or abrasive cleaner on the lid or other plastic parts Parts can become discolored scratched or even appear burned if these materials are used The stainless steel housing should be cleaned and cared for by using a traditional stainless steel cleaning material Inspect the power cord for tears frays or other damage Do not use machine if the power cord is damaged Routine ...

Page 9: ...e the surface of the seal bar and inside of the bag and try again Bag loses vacuum after being sealed Check for sharp items such as bones stems cloves and others that can puncture the bags cover them with a folded paper towel and vacuum in a new pouch Some fruits and vegetables can release gases if not properly prepared before storing Make sure to blanch or freeze food before packaging If in doubt...

Page 10: ...EMA 5 15P Pump Type Oil 1 5HP Oil 1 5HP Pump Power 1 4 HP 1 4 HP Pump Life 200 000 Cycles 200 000 Cycles Vacuum Time 20 40 Seconds 20 40 Seconds Seal Time 0 6 Seconds 0 6 Seconds Features Digital Vacuum Pressure Display Traditional Analog Pressure Gauge Removable Seal Bar Easy Check and Fill Oil Pump Adjustable Vacuum And Seal Time Digital Vacuum Pressure Display Traditional Analog Pressure Gauge ...

Page 11: ...been removed or altered Damage or failure due to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects and damage due to improper maintenance wear and tear misuse abuse vandalism or Act of God Any action for breach of this warranty must be commenced within 1 year of the date on which the breach occurred No modification of this...