Carefully inspect the control and packaging for shipping 

damage. In the event of shipping damage, please contact 

the carrier for claim information. Our customer service de

-

partment can assist you with any missing or damaged parts.

 

To avoid unintentional steambath   

operation, do not locate the control where other controls, 

accessories, shower heads, valves, body sprays or similar 

within the shower could cause confusion or interfere with 

the MrSteam control’s intended use and function.
Do not use any iTempoPlus

®

, iTempo

®

, HomeWizard

®

 or 

iGenie

®

 controls without reading and understanding the 

respective Installation and Operation Manual and MrSteam 

steam generator Installation and Operation Manual. Failure 

to read and  understand these instructions may result in an 

inoperative or hazardous installation.
 

A peel and stick warning sticker is provided 

in the MrSteam steam generator Installation, Operation 

and Maintenance Manual. This manual is provided with 

every steam generator. The warning sticker must be read 

and permanently affixed in a conspicuous location near the 

steam room. Failure to read and affix this warning sticker in 

a conspicuous location may result in serious injury or death. 

Please call MrSteam at 800 767-8326 for a free replacement 

or if you have any questions regarding the warning sticker. 
Install the iTempo or iTempoPlus controls according to 

installation instructions. Failure to install according to in -

structions will result in an inoperative control or hazardous 

overheating or inadequate heating of the steam room. 

Failure to install according to instructions will result in an 

inoperative control and overheating of the steam room.

IMP ORTA N T  NO TE: 

If the desired location for the control 

is outside the steam room a Remote Temperature Probe 

(MSTS) must be installed inside the steam room. Contact 

CA UTI ON

!

MrSteam technical service 800-614- 7411for 

more information on the Remote Temperature 

Probe.
 

Do not route iTempoPlus, iTempo, 

HomeWizard or iGenie control wiring inside conduit 

together with power lines or close to hot water or 

steam piping. Doing so may result in an inoperative 

or hazardous installation. 
 

Do not alter or modify any MrSteam 

product. Doing so may result in an inoperative or 

hazardous installation and will void the warranty.

IMP ORTA N T  NO TE S:

Turn power to the steam generator OFF before 

connecting the control to the generator. Failure 

to turn the power off will result in an inoperable 

control.

 

Wizard or iGenie controls with anything other 

than a MrSteam iTempo compatible steam gen

-

erator. MrSteam residential steam generators 

with serial numbers lower than 900000, or any 

other brand of steam generator are not to be op

-

erated with iTempo controls. Doing so may result 

in an inoperative installation.

-

tion and maintenance information. Leave this 

document with the homeowner. Do not discard 

this document.

if the steam generator is damaged or otherwise 

not functioning properly. Doing so may result in 

an inoperative or hazardous installation.

W AR N ING

!

W AR N ING

!

W AR N ING

!

Summary of Contents for mr.steam Basic Butler

Page 1: ......

Page 2: ...iTEMPO iTEMPOPLUS CONTROLS Installation Operation Maintenance Manual mr steam Feel Good Inc https usbathstore com...

Page 3: ...rnings in this manual before installing or using a steam room 4 To reduce the risk of injury A The wet surfaces of steam enclosures may be slippery Use care when entering or leaving B The steam head i...

Page 4: ...s injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or product damage IMP ORTA NT NO TE This highlights information that is especially rele...

Page 5: ...ntrols according to installation instructions Failure to install according to in structions will result in an inoperative control or hazardous overheating or inadequate heating of the steam room Failu...

Page 6: ..._________________________________________________________________ 5 Drawings for Illustrative Purposes Only 21 2 41 2 1 4 3 8 3 4 1 5 5 33 4 12 long pigtail Dimensional Information for the Round and...

Page 7: ...of personal preference If the control is installed inside the steam room the control must be located location representative of the desired steam bathing temperatures Do not locate the control above o...

Page 8: ...ct one end of the cable to the steam generator connector NO TE The connector is keyed with the flat facing up The control cable is the same at both ends STEP 4 Diagram 3 Firmly connect the other end o...

Page 9: ...res to silicone rubber and adheres to glass wood metal porcelain ceramic tile painted surfaces many plastics and rubber Surfaces must be clean and dry Apply thin layer of product Fit together and supp...

Page 10: ...steam Steam will begin to flow a few minutes after the control is turned ON The duration re quired for the steam room to reach steam bathing temperatures depends on the steam room construction and st...

Page 11: ...perature of 110 F will be used the next time the control is turned on If the control times out at 60 minutes not manually turned off then the previous user tem perature setting will be used when the s...

Page 12: ...IT Diagram 1 When the generator is first powered up or after a power interruption the clock display flashes and the clock is ready to be set up N OTE even if the clock has not been set N OTE The cloc...

Page 13: ...the steambath duration time on the clock The control is pre set and will display a TIME setting of 20 minutes de fault setting With the TIME or CLOCK displayed press the UP or DOWN keys Diagram 5 to s...

Page 14: ...mfort and safety levels MEM ORY FEAT URE If the control is turned off manually before it times out then the default settings of 20 minutes and 110 F will be used the next time the control is turned on...

Page 15: ...tic oil into the steam tor on Then press the AROMA key The Aroma indicator will be displayed The AromaSteam turns off automatically when the steam genera tor stops heating Press the AROMA key to turn...

Page 16: ...iTempoPlus call MrSteam technical service for replacement parts NO TE Replacement of the decorative covers requires removal and reinstallation of the control from the mounting surfaces Warranty To reg...

Page 17: ...eam From Bathroom to Spa iDream Pack age iGenie iSizing iSteam MusicTherapy Spa Package Steam Home Steam Therapy Sussman Valet Package Virtual Spa System Voice Genie and Voice Wizard are registered tr...

Page 18: ...am emission would contact door seals STEP 2 Install steamhead with the oil well facing up as shown Hand tightening is sufficient when teflon or equal pipe thread sealing com pound is used IMPORTANT NO...

Page 19: ...peration and Maintenance Manual Linear Steam Head Residential Model 144080 ____________________ MP _O _ RT _ AN _ T _Le _ave _th _is _ ma _ teri _al _ wit _ h t _ he _ ho _ me _ ow _ner _ IMPORTANT Le...

Page 20: ...steam heads may result in steam head operation where incidental contact by the bather with direct steam emission may occur Do not locate the steam head in any location where the steam emission zone is...

Page 21: ...to the steam outlet Failure to follow these instructions may result in a leak within the wall cavity or result in a hazardous condition and or personal injury See the Installation and Operation Manual...

Page 22: ...ig 2 for a diagram of the steam emission zone Failure to follow these instructions may result in a hazardous condition scalding or personal injury Do not install a Linear Steam Head in a tub or acryli...

Page 23: ...ith leaks moisture and property damage from leaks STEP 4 Use a level to ensure the steam head is level see Fig 3 and the steam head face is flush or recessed 1 8 from the finished wall surface Install...

Page 24: ...m Head as possible see Fig 5 STEP 2 After the finished wall surface has been installed use high temperature silicone around the steam outlet as required to make a waterproof seal Do not use grout in p...

Page 25: ...ersonal injury Plumbing without proper thread sealant may result in a leak within the wall cavity and cause problems associatedwith leaks moisture and property damage from leaks DO NOT use black iron...

Page 26: ...t between a steam bather and direct steam emissions may cause personal injury STEP 1 Never install remove or adjust a diverter into the linear steam head when the steam head is hot or if steam in turn...

Page 27: ...cause personal injury AromaTray The AromaTray is for use with MrSteam Essential Oils Place a few drops of MrSteam Essential Oils in the AromaTray as shown and allow the oil to mix with the steam to pr...

Page 28: ...the video Use only these installation instructions for a safe and problem free installation P104481 Linear Steam Head SteamHead only 104483 LSH Faceplate 104484 Diverter for Linear SteamHead 104482 A...

Page 29: ...rSteam Aroma fragrances must be disposed of as hazardous waste Avoid fragrance contact with eyes May cause mild eye irritation Ingestion may cause irritation nausea vomiting Fragrance vapors may cause...

Page 30: ...ry Time Club Therapy CT Day Spa Digital 1 Express Steam Feel Good Inc From Bathroom to Spa HomeWizard iButler iGenie iSpa Package iSteam iTempo i Tempo Plus Linear Steamhead Making Wellness a Way of L...

Page 31: ...h use A time delay allows the water to cool down about two hours before it drains resulting in a safe and gentle operation BOX CON TEN TS AutoFlush System Valve with Cord Installation Instructions A S...

Page 32: ...ot provided can be added 3 Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown Do not drain into a steam enclosu...

Page 33: ...toFlush System valve will open and may discharge boiling water SW E AT FITTIN GS When using sweat fittings use only tin base solder with a melting point below 600 degrees F Do not overheat Ends of wat...

Page 34: ...The condensation pan is equipped with an integral 3 4 NPT fitting mr steam Technical Specifications Condensation Pan 103867 104402 MODEL PROJECT INFORMATION 103867 104402 Notes Location Architect Engi...