TROUBLESHOOTING
Metering pump does not prime
1. Check if voltage is available.
2. Check liquid level in scent container. Replenish liquid, if necessary.
3. Check for air bubbles in the suction hose or the pump head.
To eliminate air bubbles see: Priming Pump.
4. Check valves for contamination. Clean valves, if necessary.
5. Check filter in container for contamination. Rinse filter under clean water.
Metering pump does not inject oil into steam room
1. Check if voltage is available.
2. Check liquid level in scent container. Replenish liquid, if necessary.
3. Check for air bubbles in the suction hose or the pump head.
To eliminate air bubbles see: Priming Pump.
4. Check valves for contamination. Clean valves, if necessary.
5. Check filter in container for contamination. Rinse filter under clean water.
6. Check the pressure hose for kinking or jamming. Straighten or replace.
7. Check if liquid is freely flowing through the atomizing nozzle when the metering
pump is energized. Apply compressed air through the atomizing nozzle.
Attach the compressed air at the point of connection of the pressure hose.
Metering pump oil delivery too much or too little
See page 8 or call Sussman-Automatic Corp. 1-800-76 STEAM
TECHNICAL SPECIFICATIONS
Dimensions:
7” L x 6.5” W x 4.5” H
_______________________________________________________
Weight:
5 pounds
_______________________________________________________
EN 60335, UL-CSA
_______________________________________________________
Motor voltage
120 VAC, 50/60 Hz
Power consumption, total [W]
12 Watt
_______________________________________________________
List of Spare Parts
Description
Part No.
Pump Head
103861
Pressure/Suction Hose
EO1-1032
(ordered by the foot)
Rebuild Kit