Metering pump does not prime

1. Check if voltage is available.
2. Check liquid level in scent container. Replenish liquid, if necessary.
3. Check for air bubbles in the suction hose or the pump head.

To eliminate air bubbles see: Priming Pump.

4. Check valves for contamination. Clean valves, if necessary.
5. Check filter in container for contamination. Rinse filter under clean water.

Metering pump does not inject oil into steam room

1. Check if voltage is available.
2. Check liquid level in scent container. Replenish liquid, if necessary.
3. Check for air bubbles in the suction hose or the pump head.

To eliminate air bubbles see: Priming Pump.

4. Check valves for contamination. Clean valves, if necessary.
5. Check filter in container for contamination. Rinse filter under clean water.
6. Check the pressure hose for kinking or jamming. Straighten or replace.
7. Check if liquid is freely flowing through the atomizing nozzle when the metering

pump is energized. Apply compressed air through the atomizing nozzle.
Attach the compressed air at the point of connection of the pressure hose.

Metering pump oil delivery too much or too little

See page 8 or call Sussman-Automatic Corp. 1-800-76 STEAM

TECHNICAL SPECIFICATIONS

Dimensions:

7” L x 6.5” W x 4.5” H

_______________________________________________________
Weight:

5 pounds

_______________________________________________________
EN 60335, UL-CSA

_______________________________________________________
Motor voltage

120 VAC, 50/60 Hz

Power consumption, total [W]

12 Watt

_______________________________________________________

List of Spare Parts

Description

Part No.

Pump Head

103861

Pressure/Suction Hose

EO1-1032

(ordered by the foot)

Rebuild Kit

104159

Summary of Contents for mr. steam AromaFlo

Page 1: ...mr steam Feel Good Inc AromaFlo Installation Operation Manual...

Page 2: ...struc tions you will notice warning and caution symbols This blocked information is important for the safe and efficient installation and operation of this generator These are types of potential hazar...

Page 3: ...umps outdoors 3 Do not install AromaFlo Pumps in a location where water could freeze 4 Do not install AromaFlo Pumps near flammable or corro sive materials and chemicals Installation in areas having h...

Page 4: ...omaFlo box 2 Unscrew the cover from the Mr Steam scent container and discard 3 Insert the suction hose with the open end from below through the hole in the container cover see Fig 3 4 Insert the filte...

Page 5: ...mp line cord 120V 90 T Atomizer nozzle Pressure hose AromaFlo pump Suction hose Scent Container Steam solenoid with electrical box Typical MrSteam Commercial steam generator Electrical connection to D...

Page 6: ...s on 120VAC 50 60hZ power supply Refer to nameplate on AromaFlo pump If the power cord of the meter ing pump is damaged it must be replaced by the Sussman Automatic service depart ment or similarly qu...

Page 7: ...ring connections Fully Assembled The electrical outlet shown is for AromaFlo Pump connection only Make no other connections to this outlet Other connections may result in circuit overload CAUTIO N For...

Page 8: ...Continue until the injector is full of liquid 6 If you have drawn up the injector completely and no liquid is in the injector remove the injector hose from the pressure valve 7 Drain injector Repeat s...

Page 9: ...____________________________ 0 106 Oz 7 min 30 sec ________________________________________________________ 0 123 Oz 8 min 45 sec ________________________________________________________ Factory Setti...

Page 10: ...ee page 4 Installation of Pressure Hose IMPORTANT NOTE The valve plate must be level in the pump head Maintenance of Pressure Valve 1 Disconnect power supply 2 Unscrew pressure end nut and remove pres...

Page 11: ...if necessary 5 Check filter in container for contamination Rinse filter under clean water 6 Check the pressure hose for kinking or jamming Straighten or replace 7 Check if liquid is freely flowing th...

Page 12: ...AY IN THE PERFORMANCE OF ITS OBLIGATIONS UNDER THIS WARRANTY DUE TO CAUSES BEYOND ITS CONTROL SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS AND OR DO NOT ALLOW THE EXCLUSI...

Reviews: