Condensate Pump:
A condensate pump is Standard on some models and Optional on all models. Installer must check unit to
see if a condensate pump has been provided with case.
WARNING TO INSTALLER
Installer must determine if case was provided with condensate pump. Failure to hook up
pump hose to drain will cause water on floor and cause a slip hazard.
CONDENSATE PUMP
DRAIN TUBE
CONDENSATE PUMP
CONDENSATE
DRAIN TUBE
DRAIN TUBE
EXIT LOCATIONS
DRAIN TUBE
EXIT LOCATIONS
DRAIN TUBE
EXIT LOCATIONS
DRAIN TUBE
EXIT LOCATIONS
Instead of using heat energy to remove condensate run off from evaporator coil a condensate pump pumps
the water to a nearby drain.
-The Condensate Pump is provided with 50’ of clear 1/2 OD x 3/8 ID tubing that must be run out of base
area to a drain.
-There are several Drain Tube exit locations provided in base as noted in drawing above. Plugs or caps will
need to be removed in desired exit location.
-Hose can be run entire 50’ in any direction as required, but no higher than 20’ from pump base. A check
valve is provided in pump to prevent water from flowing back into reservoir. For best efficiency extend
hose level below or level of pump base to create a siphoning effect. Never run hose to or through an area
below freezing or freezing water will block tube.