49
Hotkey Activation
Description, Specifications, SS Software, and Operation Manual
Federal Signal
www.fedsig.com
Cycling the three Relay Outputs
• Off times and on times 0 to 999 seconds
Calling another activation key
The 24 activation buttons activate functions 1 to 24. You can use the rear mounted
activation to activate functions 1 to 20 or you can modify jumpers to use the rear mounted
inputs as additional activation inputs.
You can configure each activation function for the following:
• Auto Prompt Send
• Auto Send
Auto Prompt Send Auto Prompt Send prompts you to press the SEND button after an
activation button has been pressed. The LCD displays the name of the function
activated.
F01:
SEND to Transmit
Once done, the unit sends out the codes for that function.
Auto Send Auto Send sends the codes out when you press an activation button or closes
a remote activation input without prompting you to press SEND. The LCD
displays the name of the function activated.
Sending:
Function Name
Auto Prompt Send Auto Report
prompts you to press the SEND button after an activation
button has been pressed. After the activation, the polls the sites it is configured
for.
Auto Send Auto Report
sends the codes out when you press an activation button
or closes a remote activation input without prompting you to press SEND. After the
activation, the polls the sites it is configured for.
You can program activation buttons as Manual. When you press a button, the
prompts you for where the message is to be sent: All, Zone, or Site. You can only use
Manual with Digital functions.
Press CLEAR to stop the process and return to the STANDBY screen.