12
General Description
Series C
Federal Signal www.fedsig.com
configure each relay to activate when the unit has not been polled in 30 minutes, when
an RTU reports a fault, or when PTT or Carrier Detect are active.
Activation Buttons
Located on the front panel of the are twenty-four programmable activation
buttons that activates functions one through twenty-four.
Configure each activation function for Auto Prompt Send or Auto Send. Auto Prompt
Send prompts you to press the SEND button after an activation button has been pressed
before initiating the activation. Auto Send sends the code out when you press the
activation button without being prompted to press SEND. The same method is used with
Auto Prompt Send Auto Report and Auto Send Auto Report modes, which include and
automated system-wide poll after activation. You can print each activation and status
reports to a printer.
Remote Activation Inputs
Located on the back of the are twenty external activation inputs that can be
driven by a momentary contact closure. These inputs are optically isolated and activate
buttons one through twenty. Debounce time for remote inputs is 250 ms. Inputs should be
closed > 250 ms and released after the activation. An input held closed for extended time
will not generate multiple activations but it will prevent other inputs from activating until
the input is released. These twenty external (rear mount) inputs are factory set to activate
activation inputs one through twenty. Modify the jumpers on the internal PCB to allow the
inputs to be used for additional functions. For example, use the remote inputs as inputs
twenty-one through forty or forty-one through sixty. See “Table 5 Input Board Addressing”
Transceiver Interface
The transceiver interface features a balanced 600-ohm input and output (optional
10 kilohms) and can accept a wide range of transceiver types and levels. The transmit
audio from other encoding equipment can be interrupted during the transmissions of
the by the PTT relay. The unit also monitors if other equipment is currently
transmitting before attempting to transmit. Carrier detect can work with either polarity or
from a VOX.
Ordering Information
Table 1 Ordering Information
Part Numbers
Description
Desk Mount Local Activation Point, US
R
Rack Mount Local Activation Point, US 19-inch
EU
Desk Mount Local hardware activation point, EU
UK
Desk Mount Local hardware activation point, UK
MNC-MNS
1
Noise Canceling Microphone
S
Operating System
Windows
®
based program used to configure and active functions on
the
Compatible with
• Desktop Operating Systems: Windows 10
• Server Operating Systems: Server 2012 and Server 2016
COMMANDER1LE CommanderOne
®
Cloud Service