background image

Safety Message to Installers and Service Personnel of Warning Light Equipment

People’s lives depend on your proper installation and servicing of Federal Signal products. It is important 

to read and follow all instructions shipped with this product and the original product. Listed below are 

some other important safety instructions and precautions you should follow:
•  To properly install this device, you must have a good understanding of automotive electrical 

procedures and systems, along with proficiency in the installation and use of safety warning 

equipment.

•  DO NOT install equipment or route wiring in the deployment path of an airbag. 
•  If a vehicle seat is temporarily removed, verify with the vehicle manufacturer if the seat needs to be 

recalibrated for proper airbag deployment.

•  When drilling into a vehicle structure, ensure that both sides of the surface are clear of anything that 

could be damaged.

•  In order for the device to function properly, a good ground connection must be made. At a minimum, 

it must be attached to a solid metal body or chassis part that will provide an effective ground path as 

long as the light system is to be used.

•  Locate light control so the VEHICLE and CONTROL can be operated safely under all driving 

conditions.

•  Do not attempt to activate or deactivate light control while driving in a hazardous situation.
•  This product controls high intensity lighting devices. To prevent eye damage, DO NOT stare into the 

light beam at close range.

•  Frequently inspect the light to ensure that it is operating properly and that it is securely attached to 

the vehicle.

•  File these instructions in a safe place and refer to them when maintaining and/or reinstalling the 

product.

•  Failure to follow all safety precautions and instructions may result in property damage, serious injury, or 

death.

Overview

The Model 330104 SMC1 is a directional light controller. It is designed to operate the full selection of 

Federal Signal SignalMaster directional light bars from four to eight light heads, either continuous or split, 

at 12 V or 24 V. The control circuitry is protected against reverse polarity by a 2 A fuse and a diode. The 

light bar requires its own appropriately sized fuse. 
This model provides six distinctive directional signals. There are standard left-arrow, center-out, and 

right-arrow patterns as well as special left-arrow, center-out, and right-arrow patterns that comply with 

CAC Title 13, Article 22 if used with the appropriate SignalMaster directional light bar in Tables 1 and 2 on 

page 2.

Instructions for the Model 330104 SMC1 

SignalMaster

 Light Bar Controller

2562118D  REV. D1 0420

Summary of Contents for SignalMaster 330104 SMC1

Page 1: ...operated safely under all driving conditions Do not attempt to activate or deactivate light control while driving in a hazardous situation This product controls high intensity lighting devices To prev...

Page 2: ...r use when a directional signal may not be appropriate One pattern can be selected from the ten patterns available which include seven standard patterns and three patterns that are compliant with CAC...

Page 3: ...Bracket 8573070 2 Lockwasher Ext Tooth 1 4 inch 7075A007 2 Screw Hex Head 1 4 20 TAPTITE 7011164 08 Installing the SignalMaster Light Bar Install the light assembly as described in the instructions i...

Page 4: ...ed as shown here if it better suits your mounting requirements NOTE Only oneBracket is supplied Thread Forming Screws Installer Supplied Connecting Power to the Controller HIGH CURRENT ARCING Do not c...

Page 5: ...other electrical connections have been made To run between the fuse and the SignalMaster use a properly sized red wire For wire gauge recommendations see Table 5 5 Select a termination point for the...

Page 6: ...en Orange Violet Gray Yellow Blue 14 AWG Ground Connection Binding Screw for Ground Wire 18 AWG Minimum Power Wire from Controller Connect to Ignition or Battery Draws 7 mA 0 007 A at Battery Red Red...

Page 7: ...can select after the installation and wiring of the SignalMaster system is complete For the functions of the controller buttons see Figure 3 and Operating the SignalMaster Controller on page 9 Figure...

Page 8: ...heads on the SignalMaster Selecting a Standard Warn Pattern In the default Standard Mode each time the WARN button is pressed the active warn pattern changes to the next in the sequence See Table 5 o...

Page 9: ...ly or if any of the lamps remain illuminated when the control is off disconnect the power connector from the controller and contact the nearest service center Failure to follow these safety precaution...

Page 10: ...tting Technical Support For technical support please contact Federal Signal Corporation Service Department Phone 1 800 433 9132 Email empserviceinfo fedsig com Getting Repair Service The Federal Signa...

Page 11: ...o order replacement parts call Customer Support at 1 800 264 3578 7 a m to 5 p m Monday through Friday CT or contact your nearest distributor Table 8 Replacement Parts Qty Description Part No 1 Contro...

Page 12: ...y Park Illinois 60484 3167 www fedsig com Customer Support Police Fire EMS 800 264 3578 1 708 534 3400 Work Truck 800 824 0254 1 708 534 3400 Technical Support 800 433 9132 1 708 534 3400 Copyright 19...