5
Installation and Maintenance Instructions
Models QL64-BTT, QL64-TURN,QL64-ARROW, and QL64-BACKUP
4. The QuadraFlare warning light Models QL64-BTT,
QL64-TURN, QL64-ARROW, and QL64-BACKUP have
three 12-inch long wires, which exit out the back of the unit,
for making electrical connections.
NOTE: The white wire is not used in Models QL64-TURN,
QL64-ARROW, and QL64-BACKUP.
5. Complete the electrical connections as described in the
Electrical Connections section.
6. See Figure 1. Align the QuadraFlare warning light assembly
with the previously inserted rubber rivet nuts and secure with
the provided #6 x 2.0" screws.
Electrical Connections
To make electrical connections, proceed as follows:
1.
Model QL64-BTT.
The QuadraFlare warning light assembly is designed to
operate on 12 VDC. Three 12-inch long lead wires are
supplied for making electrical connections to the QuadraFlare
warning light assembly.
a. Using 18-gauge (minimum) wire, connect the red (+) lead
to the positive power source terminal for BRAKE mode,
and the white (+) lead to a different positive power source
terminal for TAIL mode. The black (-) lead should be
connected to the negative power source terminal.
b. Energize the supply circuit and test the QuadraFlare
warning light assembly for proper operation.