![Federal Signal Corporation Pathfinder Installation And Maintenance Instructions Manual Download Page 26](http://html.mh-extra.com/html/federal-signal-corporation/pathfinder/pathfinder_installation-and-maintenance-instructions-manual_548439026.webp)
Chapter 5: Testing the Pathfinder Installation
Pathfinder
TM
26
Table 5.1
Pathfinder Switch Default Programming
Switch
Default Function
Slide Switch 1
Relay 1 ON, Relay 7, 8 – 90 FPM Alternate Flash,
Lightbar – Pattern 10, Front Cutoff
Slide Switch 2
Relay 1 ON, Relay 2 ON, Relay 7, 8 – Double 120 FPM Alternate
Flash, Horn Ring Transfer, Lightbar – Pattern 17
Slide Switch 3
Relay 1 ON, Relay 2 ON, Relay 3 ON, Relay 4 ON, Relay 7,
8 – Common Quad 95 FPM Alternate Flash, Horn Ring Transfer,
Siren Enabled, Lightbar – Pattern 26, Flash White Enable
Rotary – Radio
Radio Re-Broadcast
Rotary – Manual Standby
Rotary – Wail*
Wail Horn Ring Transfer
Rotary – Yelp*
Yelp Horn Ring Transfer
Rotary – HF*
Horn Siren Control, Horn Ring Transfer
Rotary – Tone 1* Priority
Rotary – Tone 2* Dual Tone (Wail/Yelp)
Volume Switch
Turns Off Keypad Backlighting
*Siren Tones Dependent on Slide Switch 3
Table 5.2
Pathfinder Button Default Programming
Button
Default Function
BTN 1
Air Horn
BTN 2
Lightbar Left Alley
BTN 3
Step 1 – Lightbar Takedown
Step 2 – Lightbar Scene, Relay 5 ON
BTN 4
Lightbar Right Alley
BTN 5
Lightbar Cruise Pattern 2
BTN 6
Lightbar Dim
BTN 7
Relay 6 ON (12V) (8 Second Timer)
BTN 8
Manual Siren
BTN 9
Lightbar SM LRCO