Safety Messages

Description, Specifications, Installation, Operation, and Service Manual

Safety Messages

  

It is important to follow all instructions shipped with this product. This device is to be 

installed by trained personnel who are thoroughly familiar with the country electric 

codes and will follow these guidelines as well as local codes. 

Planning

•  If suitable warning equipment is not selected, the installation site for the Informer15 

Speaker is not selected properly or the Informer15 Speaker is not installed properly, 

it may not produce the intended optimum audible warning. Follow Federal 

Emergency Management Agency (FEMA) recommendations. 

•  If Informer15 Speakers are not activated in a timely manner when an emergency 

condition exists, they cannot provide the intended audible warning. It is imperative 

that knowledgeable people, who are provided with the necessary information, are 

available at all times to authorize activation. 

•  When Informer15 Speakers are used out of doors, people indoors may not be able to 

hear the warning signals. Separate warning devices or procedures may be needed to 

effectively warn people indoors. 

•  The sound output of Informer15 Speaker is capable of causing permanent hearing 

damage. To prevent excessive exposure, carefully plan placement, post warnings, and 

restrict access to areas near sirens. 

•  Activating the Informer15 Speaker may not result in people taking the desired 

actions if those to be warned are not properly trained about the meaning of warning 

sounds. Users should follow FEMA recommendations and instruct those to be 

warned of correct actions to be taken.

After installation, service, or maintenance, test the system to confirm that it is operating 

properly. Test the system regularly to confirm that it will be operational in an emergency. 

Safety Messages to Installers

People’s lives depend on your safe installation of our products. It is important to follow 

all instructions shipped with this product. This device is to be installed by a trained 

electrician who is thoroughly familiar with the National Electrical Code and/or Canadian 

Electrical Code and will follow the NEC and/or CEC Guidelines as well as all local 

codes. This Informer15 Speaker should be considered a part of the warning system and 

not the entire warning system. 
The selection of the mounting location for this Informer15 Speaker, its controls and the 

routing of the wiring are to be accomplished under the direction of the Facilities Engineer 

and the Safety Engineer. In addition, listed below are some other important safety 

instructions and precautions you should follow:
•  Electrocution or severe personal injury can occur when performing various 

installation and service functions such as making electrical connections, drilling 

holes, or lifting equipment. Therefore only experienced electricians should install 

Summary of Contents for Informer15 I-IP15

Page 1: ...tion Specifications Installation Operation and Service Manual 25500494 Rev A0 0918 Printed in U S A Copyright 2018 Federal Signal Corporation Informer15 Speaker Model I IP15 IP Enabled Indoor Outdoor...

Page 2: ...is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness for a particular purpose and any warran...

Page 3: ...w 8 Features 9 Ordering Information 10 Specifications 10 Installation 11 Flat Surface Mounting 12 Opening the Housing 13 Wiring to the Control Board 13 Closing the Housing 15 Operations 16 Testing 17...

Page 4: ...trical Requirements 10 Table 3 Environmental 10 Table 4 Physical 11 Table 5 Connectors and Jacks for Control Board 16 Table 6 Connectors and Jacks for Amplifier 16 Table 7 Visual Indications for Contr...

Page 5: ...near sirens Activating the Informer15 Speaker may not result in people taking the desired actions if those to be warned are not properly trained about the meaning of warning sounds Users should follo...

Page 6: ...cht Council Inc and or ANSI NFPA 302 Fire Protection Standard for Pleasure and Commercial Motor Craft For optimum sound distribution do not install this speaker where objects would block any portion o...

Page 7: ...tric shock do not perform any servicing other than what is contained in the operating instructions unless you are qualified to do so Refer all servicing to qualified service personnel Always test the...

Page 8: ...four external switches to activate predefined alert events The Informer15 can be programmed and configured as a standalone device to only use the inputs to activate the Informer15 This may be useful...

Page 9: ...l Each device can be remotely configured for volume and noise level adjustments Speaker as microphone for talk back feature Alerts can be sent to single devices groups or zones or all devices Wall mou...

Page 10: ...imum 30 V or 100 mA maximum speaker provides 24 Vdc 20 mA maximum for external relay Ethernet Port IEEE 802 3 10 100 Base T connection with PoE 802 3at Type 2 25 5 W Alarm Initiating Inputs Four optic...

Page 11: ...experienced electricians in accordance with national and local electrical codes acting under the direction of the installation crew safety foreman should perform installation Property damage serious...

Page 12: ...e See Figure 1 for mounting hole locations and dimensions Before drilling holes in any surface ensure that both sides of surface are clear of items that could be damaged 3 Secure the unit to a wooden...

Page 13: ...Informer15 Speaker 2 JP13 is used to provide tone messages into the IP15 via microSD memory card 3 If local activations are required use JP2 The Alarm Initiation Inputs are activated by shorting the...

Page 14: ...programmed default timeout occurs Until the CANCEL or RESET command is received You can configure the open collector relay output to open close and cycle based on a pre programmed sequence The open c...

Page 15: ...est JP1 JP6 JP8 JP9 JP4 JP5 LAN Interface Closing the Housing To close the housing do the following 1 Verify that the cover gasket is in the groove around the perimeter of the rear cover 2 If the fron...

Page 16: ...dule 1 POE 2 POE JP8 Option1 Jumper Short pins 1 and 2 for Option JP9 Option2 Jumper Short pins 1 and 2 for Option JP11 Serial Port RJ25 6 conductor mod jack JP12 Controller to Amplifier Interface JP1...

Page 17: ...the OSHA Sound Level Standard 29 CFR 1910F should not be exceeded 1 After installation is complete test the system to verify that each speaker operates satisfactorily 2 After completion of initial sys...

Page 18: ...tenance personnel should not be obscured if the exterior of device is painted Periodically inspect this device to verify that there are no foreign substances in or in front of the speaker which will r...

Page 19: ...2645 Federal Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 708 534 3400...

Page 20: ...2645 Federal Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 708 534 3400...

Reviews: