7
Safety Messages
Description, Specifications, and Installation Manual
Federal Signal
www.fedsig.com
• To reduce the risk of electric shock, do not perform any servicing other than what
is contained in the operating instructions unless you are qualified to do so. Refer all
servicing to qualified service personnel. Always test the Informer100 Speaker before
using after repairs have been made.
Ethernet Wiring
• Unless shielded or run in conduit, Ethernet wiring must be at least six feet from bare
power wiring or lightning rods and associated wires, and at least six inches from other
wire (for example, antenna wires, doorbell wires, wires from transformers to neon
signs), steam or hot water pipes, and heating ducts.
• Do not place Ethernet wiring or connections in any conduit, outlet or junction box
containing high voltage electrical wiring.
• If using a cable gland, gland must be Listed. The Informer100 Speaker has 3/4-inch
and 1/2-inch NPT entry sizes.
Symbol Definition
_A _V
Indicates to reduce the risk of fire, replace the fuse as marked.
Pay careful attention to the notice located on the equipment.
Read and understand the information contained in this manual before attempting
to install or service the siren.