background image

 

 

3.  Disconnect the 10-way IDC connector from the keypad.  Remove the p-

clip that retains the keypad wire harness.

 

 

4.  Remove the four M3 fixing screws and remove the encapsulation cham-

ber cover to gain access to the field wiring terminal block.

 

 

5.  Disconnect and label all field wiring from the twelve-pole terminal.  If 

small jumpers are fitted, remove and re-use these in the new assembly.

 

 

6.  Remove locknut from M20 adapter inside the potted PCB enclosure.

 

 

7.  Remove the six M4 fixing screws that retain the potted PCB assembly to 

the molded housing.

 

 

8.  Remove the potted PCB assembly and replace with new part.

 

 

9.  Install new part by reversing the above procedure.  Be sure to observe 

polarity of power/data line when reconnecting field wiring.

 

 

10.  Test unit for proper operation after replacement is complete.

 

F.  Replacement Parts.

Description   

 

Part No.

Headset   

 

 

K137149-01

Stubby Microphone 

K137164

Gooseneck Microphone, 150mm 

K137165

Gooseneck Microphone, 330mm 

K137165-01

Potted Relay Assembly 

K8601241

Potted PCB Assembly 

K8601274

Handset, 1m stainless steel cord 

K8601248

Handset, 3m stainless steel cord 

K8601248-01

Handset, 1.8m curly cord 

K8601249

Handset, 10m curly cord 

K8601249-01

Keypad Assy.   

 

K8601267

Keypad Assy., Microphone 

K8601267-01

III. CERTIFICATION.

Certified to EN55022: 1998 +A1: 2000, EN555024: 1998, EN61000-3-2: 2000, EN61000-

3-3: 1995, and EN60950: 2000

EEx meib  IIC T6 (Tamb -35°C to +50°C)

The ATEX certificate (BAS 01 ATEX 2306X) and the product label carry the ATEX 

group and category marking:

 

 

  II 2 G

Where: -  

  indicates compliance with directive 94/9/EC

  

  hexagon symbol, the specific marking of explosion protection

 

 

II  indicates suitability for use in surface industries

 

 

indicates suitability for use in a Zone 1 area

-5-

Summary of Contents for ez1 echo

Page 1: ...INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL EZ1 ECHO INTERCOMS 2561956B REV B 812 Printed in U S A...

Page 2: ...blank page...

Page 3: ...to ensure that it is operating properly After testing is complete provide a copy of this instruction sheet to all operating personnel Establish a procedure to routinely check the intercom installation...

Page 4: ...access to the field wiring terminal block 4 The lower moulding is supplied with three M20 cable entries suitable for glands approved Exd or Exe for connection of the following cables Data Power from C...

Page 5: ...hich contains cautionary or other information of impor tance to maintenance personnel should not be obscured After performing any maintenance test the intercom system to ensure that it is operating pr...

Page 6: ...Ensure that the sealing washer is fitted properly between the microphone base and the enclosure 5 Reinstall and connect the 2 way socket block and re install cover 6 Test unit for proper operation af...

Page 7: ...per operation after replacement is complete F Replacement Parts Description Part No Headset K137149 01 Stubby Microphone K137164 Gooseneck Microphone 150mm K137165 Gooseneck Microphone 330mm K137165 0...

Page 8: ...ver exceder a 28 Vdc 100 mA IV SERVICE The Federal factory will service your equipment or provide technical assistance with any problems that cannot be handled locally Any units returned to Federal Si...

Page 9: ...UTPUT MODULE I S SAFETY INTERFACE PCB HEADSET MICROPHONE HANDSET KEYPAD 290A4984B EExe EExd APPROVED LOUDSPEAKER EExe EExd APPROVED AUDIBLE VISUAL DEVICE 240Vac 3Amp MAX SAFE AREA V max 28 VDC I max 1...

Page 10: ...NTACT EXTERNAL SPEAKER TELEPHONE LINE TERMINAL BLOCK OPTIONS SENSITIVITY LINK FOR HIGH SENSITIVITY HANDSET HANDS FREE LINK FOR HANDSET KEYPAD or SWITCH DISTRIBUTION EARTH WIRE 1 5mm MIN SECTION ENCAPS...

Page 11: ...E TALK T 0 SPEED DIAL 2 7 8 PAGE CANCEL X PRIORTY 9 VOLUME 4 5 1 2 6 SPEED 3 E C H O KEYPAD 290A4986B M6 FIXING SCREWS AUDIO DISTRIBUTION PCB M20 THREADED ADAPTER FIELD WIRING TERMINAL BLOCK M6 EARTH...

Page 12: ...Industrial Systems 2645 Federal Signal Drive University Park IL 60484 3167 Tel 708 534 4756 Fax 708 534 4852 Email elp federalsignal com www federalsignal indust com...