INSTALLATION AND SERVICE INSTRUCTIONS

FOR

MODEL EZ1 ECHO INTERCOMS

SAFETY MESSAGE TO INSTALLERS, USERS AND MAINTENANCE PERSONNEL

 

It is important to follow all instructions shipped with this product.  This device 

is to be installed by a trained electrician who is thoroughly familiar with the Country 

Electric Codes and will follow the guidelines as well as local codes.

 

The selection of mounting location for the device, its controls and the routing of 

the wiring is to be accomplished under the direction of the facilities engineer and the 

safety engineer.  In addition, listed below are some other important safety instructions 

and precautions you should follow:

• 

Read and understand all instructions before installing or operating this 

equipment.

• 

Disconnect intercom from the power supply before any installation or 

maintenance is performed.

• 

 Power is only to be provided from the Central Control.  This intercom is 

not for stand-alone use. 

 

• 

After installation, test the intercom system to ensure that it is operating 

properly.

• 

After testing is complete, provide a copy of this instruction sheet to all 

operating personnel.

• 

Establish a procedure to routinely check the intercom installation for 

integrity and proper operation.

• 

 The product nameplate, which may contain cautionary or other informa-

tion of importance to maintenance personnel, should not be obscured in 

any way.

 

Failure to follow all safety precautions and instructions may result in property 

damage, serious injury, or death.

I. INSTALLATION.

 

A.  Unpacking.

 

 

After unpacking the unit, examine it for damage that may have occurred in 

transit.  If the equipment has been damaged, do not attempt to install or operate it.  

File a claim immediately with the carrier stating the extent of the damage.  Carefully 

check all envelopes, shipping labels, and tags before removing or destroying them.

  B. General.

 

 

The equipment comprises of a polymeric enclosure containing a potted 

printed circuit board assembly providing the communications and safety functions.  

The design incorporates intrinsically safe barriers to the handsets and other ancillary 

devices.  The relay output module is available as an optional extra.  The relay oper-

-1-

Summary of Contents for ez1 echo

Page 1: ...INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL EZ1 ECHO INTERCOMS 2561956B REV B 812 Printed in U S A...

Page 2: ...blank page...

Page 3: ...to ensure that it is operating properly After testing is complete provide a copy of this instruction sheet to all operating personnel Establish a procedure to routinely check the intercom installation...

Page 4: ...access to the field wiring terminal block 4 The lower moulding is supplied with three M20 cable entries suitable for glands approved Exd or Exe for connection of the following cables Data Power from C...

Page 5: ...hich contains cautionary or other information of impor tance to maintenance personnel should not be obscured After performing any maintenance test the intercom system to ensure that it is operating pr...

Page 6: ...Ensure that the sealing washer is fitted properly between the microphone base and the enclosure 5 Reinstall and connect the 2 way socket block and re install cover 6 Test unit for proper operation af...

Page 7: ...per operation after replacement is complete F Replacement Parts Description Part No Headset K137149 01 Stubby Microphone K137164 Gooseneck Microphone 150mm K137165 Gooseneck Microphone 330mm K137165 0...

Page 8: ...ver exceder a 28 Vdc 100 mA IV SERVICE The Federal factory will service your equipment or provide technical assistance with any problems that cannot be handled locally Any units returned to Federal Si...

Page 9: ...UTPUT MODULE I S SAFETY INTERFACE PCB HEADSET MICROPHONE HANDSET KEYPAD 290A4984B EExe EExd APPROVED LOUDSPEAKER EExe EExd APPROVED AUDIBLE VISUAL DEVICE 240Vac 3Amp MAX SAFE AREA V max 28 VDC I max 1...

Page 10: ...NTACT EXTERNAL SPEAKER TELEPHONE LINE TERMINAL BLOCK OPTIONS SENSITIVITY LINK FOR HIGH SENSITIVITY HANDSET HANDS FREE LINK FOR HANDSET KEYPAD or SWITCH DISTRIBUTION EARTH WIRE 1 5mm MIN SECTION ENCAPS...

Page 11: ...E TALK T 0 SPEED DIAL 2 7 8 PAGE CANCEL X PRIORTY 9 VOLUME 4 5 1 2 6 SPEED 3 E C H O KEYPAD 290A4986B M6 FIXING SCREWS AUDIO DISTRIBUTION PCB M20 THREADED ADAPTER FIELD WIRING TERMINAL BLOCK M6 EARTH...

Page 12: ...Industrial Systems 2645 Federal Signal Drive University Park IL 60484 3167 Tel 708 534 4756 Fax 708 534 4852 Email elp federalsignal com www federalsignal indust com...

Reviews: