Chapter 3: Wiring the e-Q2B Siren System
e-Q2B Siren System
30
Connecting the Control Head
To connect the control head to the siren amplifier:
1.
Plug the 25 ft Convergence Network serial cable into one of the three serial ports in the upper
right corner on the front of the siren amplifier (Figure 3.12).
2.
Plug the other end of the cable into the connector on the back of the control head.
3.
To provide strain relief, secure the cables with installer-supplied clamps and hold-downs.
Figure 3.13 Convergence Network connection between e-Q2B and control head
30 AMP
FUSE
RED
(+BAT)
WHT/RED
(IGN)
BLK
(-BAT)
REMOTE MIC
RADIO
PARK
2
A/H
4
AUX
6
8
BRAKE
1
33
RING
GRND
10
CYCLE
12
HORN
5
RMBLR
ENBL
RMBLR
RADIO
7
RADIO
9
RADIO
11
FEDERAL SIGNAL
CONVERGENCE NETWORK
SPEAKER OUTPUT
-POWER
-OUTPUT
-LOAD
LIMIT-
SHORT-
THERMAL-
− BLK
− GRN
+ WHT
+ RED
CONTROL HEAD MUST
BE CONNECTED TO
ONE OF THESE THREE
SERIAL PORTS
25 FT CONVERGENCE
NETORK SERIAL CABLE,
(P/N 1751357-02)
FEDERALSIGNAL
MICROPHONE
(P/N 258B577-03)
290A6811