Chapter 3: Wiring the e-Q2B Siren System
e-Q2B Siren System
17
Wiring connectors are located on the siren amplifier. Ground, ignition, and power connections are located
on the three-position, pluggable, terminal block. To maintain the reliability of the siren amplifier, do not
block the air vents or the fan (Figure 3.2).
Figure 3.1 Dimensions of the control head
6.80 in
(17.27 cm)
3.25 in
(8.25 cm)
FRONT VIEW (8616026 SHOWN)
RIGHT SIDE VIEW
AIR
HORN
BRAKE
CYCLE
RADIO
VOLUME
OFF
MANUAL
WAIL
YELP
PRTY
1.18 in
(3.00 cm)
290A6802
Figure 3.2 Dimensions of the siren amplifier
TOP VIEW
9.28 in
(23.57 cm)
10.41 in
(26.44 cm)
6.91 in
(17.55 cm)
30 AMP
FUSE
RED
(+BAT)
WHT/RED
(IGN)
BLK
(-BAT)
REMOTE MIC
7.66 in
(19.44 cm)
RADIO
PARK
2
A/H
4
AUX
6
8
BRAKE
1
33
RING
GRND
10
CYCLE
12
HORN
5
RMBLR
ENBL
RMBLR
RADIO
7
RADIO
9
RADIO
11
FEDERAL SIGNAL
CONVERGENCE NETWORK
SPEAKER OUTPUT
-POWER
-OUTPUT
-LOAD
LIMIT-
SHORT-
THERMAL-
– BLK
– GRN
+ WHT
+ RED
FRONT VIEW
8.19 in
(23.57 cm)
SIDE VIEW
3.91 in
(17.55 cm)
3.91 in
(17.55 cm)
COOLING FAN
AIR VENTS ARE
LOCATED ON
THIS SIDE
290A6801