Installation and Maintenance Manual
■
4.
Route separate supply wires of the appropriate gauge for the
light and sounder into the housing through the conduit entry.
5.
Strip a maximum of 0.25 in (6.4 mm) of wire insulation from
the ends of the power leads.
6.
See Figure 4. To connect the wires to the terminal block, insert
the stripped ends of the wires into the connector as far as
they can go, then tighten the clamping screw. The maximum
tightening torque is 4.5 in-lb (0.5 N•m).
NOTE:
If it is necessary to combine two
NEUTRAL/–
wires,
connect them to the same terminal on the terminal block.
7.
Reassemble the Model AV1-LED, restore power, and test the
unit for proper operation.
Figure 4 Wiring for separate power supplies
LINE/+ (SOUNDER)
WHITE
YELLOW
RED
LINE/+ (LIGHT)
NEUTRAL/−
PCBA
CONNECTOR
290A6507