THIS WARRANTY DOES NOT COVER DAMAGE
CAUSED BY: 

• Improper installation  
• Misuse of equipment 
• Negligent servicing 
• Improper applications 
• Preventative maintenance  
• Unauthorized modifications 
• Improper electrical supply
• Failure to follow manufacturer’s instructions and rating

plate information

• Accidents or other events beyond Fedders’ control

ENTIRE WARRANTY: 

THE ABOVE CONTAINS THE SOLE AND EXCLUSIVE
STATEMENT OF THE EXPRESS WARRANTIES AND
ASSOCIATED REMEDIES AVAILABLE WITH THE
PRODUCTS DESCRIBED. NO OTHER EXPRESS
WARRANTIES ARE MADE. ALL IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO
ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, OR
IMPLIED WARRANTIES OTHERWISE ARISING FROM
COURSE OF DEALING OR USAGE OF TRADE ARE
LIMITED IN DURATION TO ONE YEAR FROM THE
DATE OF ORIGINAL PURCHASE. IN NO EVENT SHALL
FEDDERS BE LIABLE FOR ANY INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN
IF ADVISED IN ADVANCE OF THE POSSIBILITY OF
SUCH DAMAGES. NO WARRANTIES, EXPRESS OR
IMPLIED, ARE MADE TO ANY BUYER UPON RESALE.

SOME STATES DO NOT ALLOW LIMITATIONS ON HOW
LONG AN IMPLIED WARRANTY LASTS OR DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE
ABOVE LIMITATIONS MAY NOT APPLY TO YOU. THIS
WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND
YOU MAY ALSO HAVE OTHER RIGHTS, WHICH MAY
VARY FROM STATE TO STATE. NO WARRANTIES ARE
MADE FOR UNITS SOLD OUTSIDE THE ABOVE STATED
AREAS. YOUR DISTRIBUTOR OR FINAL SELLER MAY
PROVIDE A WARRANTY ON UNITS SOLD OUTSIDE OF
THESE AREAS.

LIMITED FIVE YEAR WARRANTY:

Fedders will provide a replacement part or component
that proves to be defective in material or
workmanship.

WARRANTY LIMITATIONS: 

• Limited Warranty does not include allowances for labor

or travel expense connected with the installation of
parts, so furnished in this Limited Warranty or for field
repair, or servicing of the equipment, nor for
refrigerant used

• For warranty purposes the purchase date is established

by a proof of purchase. If a proof of purchase can not
be verified, then warranty period will be measured
from the date of manufacture plus 6 months.

• Cost of repair or replacement of consumable parts is

not covered under the terms of this warranty

• Replacement parts are warranted only for the balance

of the original warranty period

• Applies only to original installation and normal use and

service within the 48 contiguous United States, District
of Columbia and Canada 

• Applies to service performed by an authorized servicer    

WARRANTY IS VOID IF:  

• Serial plate is defaced      
• Product has defect or damage due to product

alteration, connection to an improper electrical supply,
shipping and handling, fire, flood, lightning or other
conditions beyond the control of Fedders

• Product is not installed according to Fedders’

instructions and specifications

• Product is operated in a corrosive environment

containing concentrations of corrosive agents causing
deterioration of components    

• Product is operated with indoor unit or refrigerant

control device that does not meet Fedders’
specifications

• Product is moved from original installation site
• Filters are not changed per manufacturer’s

reccomendation

OWNER’S RESPONSIBILITIES:

• Provide proof of purchase (sales receipt)
• Provide normal care and maintenance as outlined in

this manual

• Make product reasonably accessible for service
• Pay for freight, labor and travel expenses
• Pay for premium service costs for service outside

servicer’s normal business hours

• Pay for service calls related to product installation and

maintenance

LIMITED WARRANTY

Summary of Contents for AFPB24B1

Page 1: ...ing 6 Factory and Field installed Expansion Valves 6 Ductwork 7 Return Air Ducting 7 Return Air Platform Height 7 LINE VOLTAGE CONNECTIONS 7 24 VOLT CONTROL SYSTEM 8 CONDENSATE PLUMBING 8 WIRING DIAGR...

Page 2: ...ion which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without th...

Page 3: ...ndividuals specially trained and experienced in the installation of this type equipment and related system components Installation and service personnel are required by some locales to be licensed Per...

Page 4: ...E DUCT 600 FPM 24 MINIMUM RETURN GRILLE 500FPM RETURN PLATFORM LINED WITH 1 FIBERGLASS INSULATION REFER TO LOCAL CODES CLOSET AIR HANDLER Upflow Installation With Return Duct DISCHARGE DUCT 600 FPM 24...

Page 5: ...rom left hand side of air handler and re install on right hand side Change splash baffle location from left hand to right hand side of drain pan flange 4 Remove the horizontal coil support bracket fro...

Page 6: ...filter grille may be installed for closet applications If this method is not desirable cabinet extension kit No 65 1647 for A24 A30 and A36 or No 65 1649 for A42 A48 and A60 may be ordered The extens...

Page 7: ...BE TAKEN TO AVOID OVERHEATING THE TXV VALVE AND CAUSING DAMAGE TO THE INTERNAL COMPONENTS 3 Attach the bulb securely with the copper strap provided 4 Insulate the bulb thoroughly with a suitable insu...

Page 8: ...4 2 5 163 8 41 6 221 4 56 5 3 7 6 3 7 6 13 4 4 4 2 5 163 8 41 6 221 4 56 5 3 7 6 3 7 6 13 4 4 4 2 5 11 8 WARNING BEFORE PERFORMING ANY WORK ON THIS EQUIPMENT POWER SUPPLY MUST BE TURNED OFF AT THE HOU...

Page 9: ...ING IMPROPER INSTALLATION OF THE ELECTRICAL WIRING OR THE HEAT ASSEMBLY MAY RESULT IN FIRE SERIOUS PERSONAL INJURY OR DEATH UNIT FLEXIBLE TUBING HOSE OR PIPE DRAIN CONNECTION A POSITIVE LIQUID SEAL IS...

Page 10: ...0 5 3 10 5 3 kW does not include motor watts Ampacities and over current protection based on largest air handler motor load Refer to specific name plate for exact ampacity and overcurrent protection s...

Page 11: ...1 4 3 5 8 13 1 4 15 48 1 8 19 1 8 21 26 22 16 3 8 22 1 4 AFPC48B1 2 1 4 3 5 8 13 1 4 15 48 1 8 19 1 8 21 26 22 16 3 8 22 1 4 AFPC60A1 2 1 4 3 5 8 13 1 4 15 48 1 8 19 1 8 21 26 22 16 3 8 22 1 4 AFPC60B...

Page 12: ...30 1840 1770 1590 LOW 20 kW 0 35 15 kW 0 35 1360 1350 1340 1185 1080 Air flow shown at the following conditions No heat elements in air handler Decrease CFM 1 for 5 kW 7 5 kW or 10 kW heat kits Decrea...

Page 13: ...ompartment remove the cover plate from the element housing Remove cover plate Remove air handler field wiring box and discard Remove two screws 11 14 11 15 5 Cut the wire tie holding the heater plug a...

Page 14: ...other than 230 multiply temperature rise by capacity correction factor Refer to CFM tables to determine Cfm at total external static pressure in system For correction of unit output multiply the corr...

Page 15: ...TATIONS Limited Warranty does not include allowances for labor or travel expense connected with the installation of parts so furnished in this Limited Warranty or for field repair or servicing of the...

Page 16: ...r the general appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and construction at any time without notice For replacement parts ple...

Reviews: