Fedders A7D18E2B User Manual Download Page 11

9

SERVICE &
WARRANTY

ALTERNATE INSTRUCTIONS

SERVICE

OPERATION

INSTALLATION

ELECTRICAL REQUIREMENTS 

& SAFETY PRECAUTIONS

INSTALLATION

ELECTRICAL REQUIREMENTS 

& SAFETY PRECAUTIONS

INSTALLATION

WINDOW INSTALLATON

INSTALLATION

THRU-WALL INSTALLATION

INSTALLATION

TROUBLESHOOTING

SERVICE

TROUBLESHOOTING

ELECTRONIC CONTROLS

WARRANTY

MAINTENANCE

OPERATION

INSTALLATION

WINDOW INSTALLATON

INSTALLATION

THRU-WALL INSTALLATION

INSTALLATION

AIRFLOW / FILTER

Room Air Conditioner Warranty

(Within the 48 contiguous United States, state of Hawaii,
the District of Columbia, Puerto Rico, Mexico and Canada)

Full (Five Year) Parts and Labor Warranty

During the five years after the date of original purchase,
Fedders North America will, through its authorized servicers
and free of charge to the owner or any subsequent user,
repair or replace any parts which are defective in material
or workmanship due to normal use. Ready access to the air
conditioner is the responsibility of the owner.

Note: In the event of any required parts replacement within
the period of this warranty, Fedders North America
replacement parts shall be used and will be warranted only
for the period remaining on the original warranty.

Exceptions

The above warranty does not cover failure to function
caused by damage to the unit while in your possession
(other than damage caused by defect or malfunction), or by
its improper installation, or by unreasonable use of the
unit, including without limitation, failure to provide
reasonable and necessary maintenance or to follow the
written Installation and Operating Instructions. If the unit is
put to commercial, business, rental, or other use or
application other than for consumer use, we make no
warranties, express or implied, including but not limited to,
any implied warranty of merchantability or fitness for
particular use or purpose. 

THE REMEDIES PROVIDED FOR IN THE ABOVE EXPRESS
WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES
THEREFOR, NO OTHER EXPRESS WARRANTIES ARE MADE.
ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED
TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR USE OR PURPOSE, ARE LIMITED
IN DURATION TO FIVE YEARS FROM THE DATE OF ORIGINAL
PURCHASE. IN NO EVENT SHALL FEDDERS NORTH AMERICA
BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES, EVEN IF ADVISED IN ADVANCE OF THE
POSSIBILITY OF SUCH DAMAGES. NO WARRANTIES,
EXPRESS OR IMPLIED, ARE MADE TO ANY BUYER UPON
RESALE. 

Some states do not allow limitations on how long an
implied warranty lasts or do not allow the exclusion or
limitation of incidental or consequential damages, so the
above limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also
have other rights which may vary from state to state.

How to Obtain Warranty Service or Parts 

Note: Before calling for service, carefully read this Installation
and Operations manual.

For Models Installed in North America : 

First make the recommended checks in the Troubleshooting
guide. Then, if you still need assistance: 

1.  Call a CareCo authorized servicer and advise them of model

number, serial number, date of purchase and nature of
complaint. Service will be provided during normal working
hours. Contact your dealer for the name of an authorized
servicer, if unknown to you.

2. If your dealer is unable to give you the name of a servicer

or if you need other assistance, contact CareCo for the
name of an authorized servicer.

You may contact CareCo by email:

[email protected]

by calling the following toll-free number: 

1-800-332-6658

or you may write:  

CareCo, Service Department    
415 W. Wabash Ave., P.O. Box 200      
Effingham, IL 62401

For Models Installed Outside North America : 

For room air conditioners purchased for use outside North
America, the manufacturer does not extend any warranty
either expressed or implied. Consult your local dealer for any
warranty terms extended by the importer in your country.

Proof of Purchase Date 

It is the responsibility of the consumer to establish the original
purchase date for warranty purposes. We recommend that a
bill of sale, cancelled check, or some other appropriate
payment record be kept for that purpose.

Proper use and care of your air conditioner will help ensure
longer life of the unit. It is recommended to annually inspect and
clean the coils and condensate water passages. Expense of
annual inspection is the consumer’s responsibility.

Summary of Contents for A7D18E2B

Page 1: ...e la grille d corative avant pr s du tableau de commande Communiquer ces num ros lors de toute correspondance ou appel au service apr s vente ayant trait au climatiseur ENGLISH Important Safety Instru...

Page 2: ......

Page 3: ...rdinances Use copper conductors of correct wire gauge and protector size only Do not alter cord or plug end Do not remove warning label on cord Important Grounding Requirements Air conditioner has a t...

Page 4: ...des of the cabinet and the window stopmolding This size unit requires two leveling brackets Fig 3b Decorative Front Removal 1 Remove the phillips screws on both sides of the cabinet Fig 4 3 Gently pul...

Page 5: ...y downward on the outside as shown by 1 2 a bubble off on a carpenter s level This outward pitch prevents water from entering the room Installation Other Than Flush Mount In order to install the unit...

Page 6: ...indow sill position 2 Slide the filler panel out from the air conditioner cabinet until the filler panel flange contacts the window stop molding position 3 Fig 14 4 Attach the filler panel to the face...

Page 7: ...e cabinet Measure height from top of cabinet to bottom of bar Add this measurement to the thickness of wood used to build the frame This will determine the size of wall opening needed Minimum 1 thick...

Page 8: ...nsate drain The fitting should be protruding approximately 1 2 above the bottom pan when fully threaded into the condensate drain Fig 21 3 If an open drain source is used to dispose of condensate plas...

Page 9: ...et temperature will use LO fan HEAT Mode Heat models only 9 or more below the set temperature will use HI fan 4 or less below the set temperature will use LO fan Timer Control The timer can be set to...

Page 10: ...moisture removal system Window vibration poor installation Improper installation Unit removing large quantity of moisture from humid room Push plug firmly into wall outlet Replace fuse with time delay...

Page 11: ...R USE OR PURPOSE ARE LIMITED IN DURATION TO FIVE YEARS FROM THE DATE OF ORIGINAL PURCHASE IN NO EVENT SHALL FEDDERS NORTH AMERICA BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADV...

Page 12: ...agar el aparato No bloquee la circulaci n del aire hacia las rejillas de ventilaci n exteriores del gabinete No obstruya el flujo del aire hacia el interior con persianas cortinas o muebles o hacia el...

Page 13: ...ambos lados del gabinet 2 Quite las dos perillas de control control mec nico solamente 3 Tire suavemente hacia adelante mientras sostiene los dos lados del frente decorativo C mo retirar el chasis Qui...

Page 14: ...erior usando la indicaci n de un nivel de carpintero Dicha inclinaci n evitar que el agua entre en la habitaci n Instalaci n diferente al montaje a ras Para instalar la unidad de modo que se proyecte...

Page 15: ...Deslizar el panel de relleno sac ndolo del gabinete del acondicionador de aire hasta que el reborde del panel de relleno haga contacto con la moldura de tope de la ventana posici n 3 Fig 13 4 Unir el...

Page 16: ...de la madera usada para construir el marco Esto determinar el tama o necesario de la cavidad en la pared El marco debe construirse usando madera de por lo menos 1 de espesor Cuando se determine el gro...

Page 17: ...1 2 sobre la bandeja inferior cuando est completamente enroscado en el drenaje de condensaci n Fig 21 3 Si se utiliza una fuente de drenaje abierta para eliminar el producto de la condensaci n podr ha...

Page 18: ...l modo Cool El ventilador cambiar de la velocidad de ajuste a velocidad baja cuando el compresor sea apagado por el termostato Cuando el compresor se activa nuevamente el ventilador volver al ajuste o...

Page 19: ...ndicionador de aire Para PONER EN MARCHA autom ticamente el acondicionador de aire usando el modo Timer 1 Oprima el bot n Timer cuando la alimentaci n el ctrica est desconectada El indicador mostrar 0...

Page 20: ...re est sucio Limpie el filtro Consulte la secci n frente decorativo el aire no puede pasar Limpieza del filtro de aire Para descongelar seleccione la posici n FAN ventilador El acondicionador de aire...

Page 21: ...FIN EN PARTICULAR DURANTE CINCO A OS A PARTIR DE LA FECHA DE COMPRA BAJO NINGUNA CIRCUNSTANCIA FEDDERS NORTH AMERICA SE HARA RESPONSABLE POR NINGUN DA O DIRECTO INDIRECTO O CONSECUENCIAL SIN IMPORTAR...

Page 22: ...it d alimentation Si la plaque signal tique du climatiseur indique qu il doit tre aliment sous 230 volts il faut que l appareil soit prot g par son propre fusible ou disjoncteur et aucun autre apparei...

Page 23: ...s solidement des surfaces fermes en bois ma onnerie ou m tal D pose du panneau frontal d coratif 1 Retirer les vis de chaque c t du bo tier 2 Retirer les deux boutons de commande Mod les m canique uni...

Page 24: ...n d calage d une demi bulle sur un niveau bulle Cette inclinaison vers l ext rieur emp che l eau de p n trer dans la pi ce Installation autre qu un montage encastr Pour poser l appareil dans des condi...

Page 25: ...travers le trou de la glissi re dans la fen tre int rieure 7 Couper le joint en mati re plastique mousse la longueur appropri e et l ins rer entre la fen tre ext rieure et la fen tre int rieure Insta...

Page 26: ...de l ouverture n cessaire dans le mur Pour la r alisation de l encadrement utiliser du bois pais d au moins 2 5 mm 1 po Pour d terminer la largeur finale de l encadrement tenir compte du fait que les...

Page 27: ...d charge du condensat un tube en plastique ou en caoutchouc peut relier directement le raccord de tuyau la source ouverte d vacuation Si une source ferm e d vacuation plomberie structurale interne es...

Page 28: ...uelle que soit la vitesse de rotation initialement s lectionn e Lors de la remise en marche du compresseur sur commande du thermostat le ventilateur adopte de nouveau la vitesse de rotation initialeme...

Page 29: ...erie 1 Appuyer sur le bouton de la minuterie alors que l appareil N est PAS ALIMENT L afficheur pr sentera 00 Effectuer avec les touches fl ch es le r glage de la valeur affich e pour indiquer le nomb...

Page 30: ...ement Le thermostat est r gl sur une temp rature R gler le thermostat sur un niveau de l arri re du panneau decoratif frontal trop lev e temp rature inf rieure Le climatiseur refroidit mais la L appar...

Page 31: ...RS NORTH AMERICA NE SAURAIT EN AUCUN CAS TRE TENU RESPONSABLE POUR LES DOMMAGES INDIRECTS SECONDAIRES OU ACCESSOIRES SANS GARD LA CAUSE M ME AU CAS O FEDDERS NORTH AMERICA AURAIT T PR VENU DE LA POSSI...

Page 32: ...atures and specifications subject to change without notice Las caracter sticas y especificaciones est n sujetas a cambio sin previo aviso Les caract ristiques et sp cifications sont sujettes modificat...

Reviews: