Ethernet-I/P Fieldbus Expansion Unit
PAGE 23
●
Message Information Output Example (Multi Format)
(Note:PLC output ref. for Allen Bradley)
Multi Format
Output Item
Result Output
PLC Input (BCD Format)
PLC Input (ASCII Format)
Sequence
Cycle Count
216
C00
00 00
C00 to
C07
‘_____216’
C01
02 16
Date
2013-06-21
C02
20 13
C08 to
C17
‘2013-06-21’
C03
06 21
Time
10:23:36
C04
10 23
C18 to
C25
‘10:23:36’
C05
36 00
Sequence Judgment
REJECT
C06
00 01
C26 to
C29
‘REJ_’
Sequence No.
1
C07
00 01
C30 to
C31
‘_1’
~
~
~
~
~
Final Message Information
Area
(when 250 bytes are set)
C124
C124