ETC Report No. : 16-11-RBF-029-01
Sheet 3
of 41 Sheets
FCC ID:
DMOEMXSW2
3
2.2 Requirement for Compliance
(1) Conducted Emission Requirement
For an intentional radiator that is designed to be connected to the public utility (AC)
power line, the radio frequency voltage that is conducted back onto the AC power line on
any frequency or frequencies within the band 150kHz to 30MHz shall not exceed the
limits in the following table, as measured using a 50MH/50 ohms line impedance
stabilization network (LISN). Compliance with the provisions of this paragraph shall be
based on the measurement of the radio frequency voltage between each power line and
ground at the power terminal. The lower limit applies at the band edges.
Frequency
MHz
Quasi Peak
dBμV
Average
dBμV
0.15 - 0.5
66-56
56-46
0.5 - 5.0
56
46
5.0 - 30.0
60
50
(2) Radiated Emission Requirement
For unintentional device, according to §15.109(a), except for Class A digital devices, the
field strength of radiated emissions from unintentional radiators at a distance of 3 meters
shall not exceed the following values:
Frequency
MHz
Distance
Meters
Radiated
dBμV/m
Radiated
μV/m
30 - 88
3
40.0
100
88 - 216
3
43.5
150
216 - 960
3
46.0
200
Above 960
3
54.0
500
For intentional device, according to §15.209(a), the general requirement of field strength
of radiated emissions from intentional radiators at a distance of 3 meters shall not exceed
the above table.