ETC Report No. : 16-11-RBF-029-01
Sheet 34
of 41 Sheets
FCC ID:
DMOEMXSW2
34
Radiated Emission Test Results of the Band Edges
Site
:CHAMBER #2
Date
:2016-11-22
Limit
:2.4GHZ PEAK
Ant. Pol.
:HORIZONTAL
EUT
:XS WIRELESS
Model
:EM-XSW2
Power Rating
:120V 60Hz
Temp.
:23°C
Engineer
:Brian Huang
Humi.
:68 %
Test Mode
:CH LO & HI - BANDEDGE
Freq
MHz
Reading
dBuV
Correction
Factor
dB
Result
dBuV/m
Limits
dBuV/m
Over limit
dB
Detector
2400.0000
35.2
-5.8
29.4
54.0
-24.6
Average
2400.0000
53.7
-5.8
47.9
74.0
-26.1
Peak
2483.5000
35.1
-5.7
29.4
54.0
-24.6
Average
2483.5000
60.3
-5.7
54.6
74.0
-19.4
Peak
Note :
1. Result = R Corrected Factor
2. Corrected Factor = Antenna Cable Loss - Amplifier Gain (if any)
3. The margin value=Limit - Result
4. The expanded uncertainty of the radiated emission tests is 3.53 dB.