5.4 Result Data Calculation
The result data is calculated by adding the LISN Factor to the measured reading. The basic
equation with a sample calculation is as follows:
RESULT = R LISN FACTOR
Assume a receiver reading of 22.5 dBμV is obtained, and LISN Factor is 0.1 dB, then the
total of disturbance voltage is 22.6 dBμV.
RESULT = 22.5 + 0.1 = 22.6 dBμV
Level in μV = Common Antilogarithm[(22.6 dBμV)/20]
= 13.48 μV
5.5 Conducted Measurement Equipment
The following test equipment are used during the conducted test .
Equipment
Manufacturer
Model No. Calibration Date Next Cal. Date
EMI Test Receiver Rohde & Schwarz
ESCI
2015/12/05
2016/12/04
LISN
Shibasoku
563
2016/05/16
2017/05/15
LISN
Rohde & Schwarz
ESH2-Z5
2016/05/05
2017/05/04