38
VAIE 7M00
EN
Label
Application
See panel
Notes
Control input
Controlled input contacts
Panel for confi guring the controlled
inputs. To go from one input to
another (from 1 to 7), press
Next
or
Prev
.
Press
Mode
to select one of the
following modes:
-
Message input > Edit zone
-
Broadcast > Edit zone
Press
‘Edit zone’
to associate a
message with each zone
-
Not active input
-
Reset input
Press
Control
to enable or disable
control over the concerned input.
Press
Logic
to set the logic
typology attributed to the
concerned input, choosing
between:
-
Positive
(active high)
-
Negative
(active low)
Press
Trans
to choose the
operating mode:
-
Level
: the messages are
activated only for as long as the
input is activated.
-
Transition
: activation of the
messages starts with activation of
the input, but can be stopped only
by means of manual resetting or a
reset input.
Press ‘
Escape
’ to exit the screen
page.
Output
Relay outputs
Panel for confi guring the outputs.
To go from one output to another
(from 1 to 3), press
Next
or
Prev
.
Activate or de-activate (On/Off ) the
type of event to be associated with
the output in question by pressing
the appropriate buttons.
To leave the screen, press
‘
Escape
’.