background image

- 13 -

User Codes

TO ADD OR CHANGE A USER CODE

Users can be added or changed directly at the keypad. Your system can have up
to 64 different user codes, with each assigned to one of four authority levels and
to a primary partition. The authority level determines the functions that user
can perform. In addition, your system can be set up for 4-digit or 6-digit user
codes. Ask your installer which type of user codes is used in your system.

To add or change a user code, press the following:

Master User Code

User ID (01-64) 

New User Code

Auth. Level

CODE

nn

[1-4]

Authority Levels

Level Functions Allowed

1

Primary Master, access all partitions, can view log and set time, assign other user codes, all
system functions

2

Secondary Master, same as primary master except cannot change the primary master’s code

3

User, cannot assign code and cannot bypass zones

4

Limited user, same as level 3, except can disarm the system only if it was armed by another
user with level 4 authority (cannot disarm if armed with user of higher authority level).

Assigning Partitions to Users
When a user code is assigned, that user is automatically allowed to perform
system functions in the partition in which the user’s code is assigned. You can
also allow users to access other partitions and turn on open/close reporting to a
pager by using the #7 command as follows:
[#] [7] [master code] [user no.] [1, 2, 3, or 4]

where:

master code = user with authority level 1 or 2
user no. = the user that will be assigned access to other partitions
1, 2, 3, or 4 = enter the partition(s) 1-3 you want this user to have access to

enter 4 if you want this user to send open/close reports to a pager

TO DELETE A USER CODE

To delete a user, press the Code button followed by the 4-digit master user code.
Enter the the user number, then press [

] to delete. For example, to delete user

3, do the following:

Master User Code 

User ID 

 to delete

CODE

03

[

]

NOTE: 

User no. 1, the master user, cannot be deleted but it can be changed

using the ADD OR CHANGE user procedure.

Summary of Contents for OMNI-848

Page 1: ...P 2 20 01 1 8VHU XLGH ARMED READY 1 4 7 2 5 8 0 3 6 9 STAY BYPASS INSTANT CODE ARMED READY 1 4 7 2 5 8 0 3 6 9 STAY BYPASS INSTANT CODE 1 3 2 4 6 5 7 9 8 0 STAY INSTANT BYPASS CODE ARM AC LB READY ST...

Page 2: ...E SYSTEM ON 9 TURNING THE SYSTEM OFF 12 USER CODES 13 MISCELLANEOUS COMMANDS 14 TESTING THE SYSTEM 19 RECOMMENDATIONS ON SMOKE DETECTORS 20 EMERGENCY EVACUATION 21 GLOSSARY 22 FCC STATEMENT 20 TELEPHO...

Page 3: ...ON AND STAY INSIDE 1 Check to make sure the system is ready Green READY light is lit 2 Press STAY 3 Enter your 4 digit user code The On Off ARM light and the STAY light will both light REMEMBER You mu...

Page 4: ...52 Show Auto LCD only May also require code 53 User log view LCD only Also needs user code with authority level 1 or 2 54 Set Auto Time of current part All keypads by partition need user code 55 Disp...

Page 5: ...three types of keypads that can be used with this system LCD keypad alpha display Fixed Glass keypad 2 digit display LED keypad Since your system may use any of these keypads the displays of all keypa...

Page 6: ...building Zone 4 Main entrance to building Zone Description Zone Description 1 25 2 26 3 27 4 28 5 29 6 30 7 31 8 32 9 33 10 34 11 35 12 36 13 37 14 38 15 39 16 40 17 41 18 42 19 43 20 44 21 45 22 46...

Page 7: ...activate these emergency keys The emergency keys used for all keypads are shown below The following SEND HELP ALERT is programmed into my system KEYS DESCRIPTION __________________________________ 7 9...

Page 8: ...3 12 44 13 45 14 46 15 47 16 48 17 49 18 50 19 51 20 52 21 53 22 54 23 55 24 56 25 57 26 58 27 59 28 60 29 61 30 62 31 63 32 64 ____ ____ USER CODE NOTE User codes can be either 4 digits or 6 digits d...

Page 9: ...ime programmed by your installer Refer to the reference sheet for the time that has been set for your system WHEN THE SYSTEM IS NOT READY If the system is not ready to be armed the READY light will be...

Page 10: ...and the following will display LCD Keypad ON STAY PART 1 Fixed Glass Keypad STAY LED Keypad Arm and Stay LEDs lit REMEMBER You must turn the system off if you want to open the door or leave the premis...

Page 11: ...ile the system is turned off Press the BYPASS button Then enter your user code and the zone number 1 7 to be bypassed as follows BYPASS followed by your user code ZONE If the Quick Bypass feature has...

Page 12: ...1 Fixed Glass Keypad Ready LED lit LED Keypad Ready LED lit If alarms occurred when the system was on or if a trouble condition exists the display shows LCD Keypad ALM MEM ZN1 PART 1 Fixed Glass Keypa...

Page 13: ...isarm the system only if it was armed by another user with level 4 authority cannot disarm if armed with user of higher authority level Assigning Partitions to Users When a user code is assigned that...

Page 14: ...urning your system Off always requires a valid user code QUICK FORCED ON If programmed by your installer Quick Forced On allows you to turn the system on to the AWAY mode by automatically bypassing al...

Page 15: ...R PARTITIONS You can assign users access to any of the partitions in a multi partition system by doing the following 7 master code user number 1 2 3 where 1 2 3 are the partitions to which the user is...

Page 16: ...f programmed certain user codes can also be used to open a door See your installer for door numbers VIEW TIME To view the system time press 51 A typical display is as follows Dec 27 1999 08 15A SET TI...

Page 17: ...in sequence the 5 and 8 keys An acknowledgement tone sounds to indicate pager number programming has been accessed The 5 8 command is accessible only while the system is disarmed and the dialer diale...

Page 18: ...ager phone number programming mode without saving the changes If no key is pressed within 10 seconds the pager phone number programming mode times out and exits automatically without saving any inform...

Page 19: ...th In order to test your backup standby battery the following procedure should be followed 1 Unplug the transformer from the AC outlet by removing the restraining screw that secures the transformer to...

Page 20: ...ediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that you ins...

Page 21: ...and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors...

Page 22: ...r contacted by your security system over the telephone and or other communication channels when alarms are activated if your system is programmed to communicate alarms off site The central station wil...

Page 23: ...and ready they are not affected in any way by turning the burglary portion of your security system on or off Other terms used are armed system is on and disarmed system is off See ON INSTANT ON STAY a...

Page 24: ...ink to the monitoring agency central station 2 the keypad s which provide you with system status and allow you to input commands 3 security sensors such as door and window contacts motion sensors smok...

Page 25: ...echnician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from...

Page 26: ...ot reach the detectors such as in chimneys in walls or roofs or on the other side of closed doors Smoke detectors also may not sense a fire on another level of a residence or building A second floor d...

Page 27: ...if the system responds to the emergency as intended occupants may have insufficient time to protect themselves from the emergency situation In the case of a monitored alarm system authorities may not...

Page 28: ...IAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENC...