background image

LIMITED WARRANTY

Fire Burglary Instruments, Inc., a subsidiary of Pittway Corporation, and Pittway Corporation, its divisions,
subsidiaries and affiliates ("Seller"), 180 Michael Drive, Syosset, New York 11791, warrants its security equipment
(the "product") to be free from defects in material and workmanship for one year from date of original purchase,
under normal use and service. Seller's obligation is limited to repairing or replacing, at its option, free of charge for
parts, labor, or transportation, any product proved to be defective in materials or workmanship under normal use
and service. Seller shall have no obligation under this warranty or otherwise if the product is altered or improperly
repaired or serviced by anyone other than the Seller. In case of defect, contact the security professional who
installed and maintains your security equipment or the Seller for product repair.

This one-year Limited Warranty is in lieu of all other expressed warranties, obligations or liabilities. THERE ARE
NO EXPRESS WARRANTIES THAT EXTEND BEYOND THE FACE HEREOF. ANY IMPLIED WARRANTIES,
OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS PRODUCT, INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR
OTHERWISE, ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF ORIGINAL
PURCHASE. ANY ACTION FOR BREACH OF ANY WARRANTY, INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANTABILITY, MUST BE BROUGHT WITHIN 60 MONTHS FROM DATE OF
ORIGINAL PURCHASE. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL
OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED,
OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED
BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Some states do not allow limitation on how long an implied
warranty lasts or the exclusion or limitation of incidental or consequential  damages, so the above limitation or
exclusion may not apply to you.

Seller does not represent that the product may not be compromised or circumvented; that the product will prevent
any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases
provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may
only reduce the risk of a burglary, robbery, fire or other events occurring without providing an alarm, but it is not
insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a
result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY
DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. HOWEVER,
IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING
UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S
MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT,
WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty gives you
specific legal rights, and you may also have other rights, which vary from state to state. No increase of alteration,
written or verbal, to this warranty is authorized.

Subsidiary of PITTWAY CORPORATION

180 Michael Drive, Syosset, New York 11791

Copyright © 2000 PITTWAY CORPORATION

¬1"l

N9942-2  1/01

Summary of Contents for OMNI-408

Page 1: ...6HFXULW 6 VWHP 2 20 01 1 2 20 01 1 8 8 8VHU XLGH N9942 2 1 01 ...

Page 2: ...n Instant Mode and Stay Inside 11 To Turn the System On In Instant Mode 12 To Bypass a Zone 12 To Unbypass a Zone 13 Turning the System Off 13 USER CODES 15 Adding Changing a User Code 15 Deleting a User Code 15 PAGING FEATURE 16 Follow Me Displays 16 Changing the Pager Follow Me Phone Number 16 KEYPAD FUNCTIONS 18 System Turn On Maid Code 18 Send Help Conditions 18 Set Time and Date 20 Turn Chime...

Page 3: ...press the DISARM button on your keyfob The ARMED LED goes out System Turn On Stay Inside Check to make sure the system is ready Green READY LED is lit Press STAY followed by your User Code The ARMED and STAY LEDs light You must turn the system off if you want to open the door or leave the premises after the exit time has passed System Turn On Stay Inside Instant Mode Check to make sure the system ...

Page 4: ...tem time hours minutes month day year 4 Zone Directory LCD only Displays listing of zones in system 55 Display Firmware Version LCD only Displays version of your OMNI 408 firmware 56 Display Keyfob Battery Status All keypads Allows you to test battery status of your keyfob Upon entry of this mode press any button on the keyfob and the keypad will display if your battery is low 58 Change View Pager...

Page 5: ...use either the OMNI KP OMNI LCD or OMNI LED keypads The OMNI KP keypad displays the system status with fixed words the OMNI LCD keypad displays two lines of text and the OMNI LED keypad displays the current zone status including alarms bypasses and faults using LEDs Each condition causes the LEDs to operate differently Throughout this guide the following conventions are used to display the keystro...

Page 6: ... following SEND HELP ALERTS can be programmed into your system Both keys must be pressed at the same time to activate the alert The keys you press depend on which type of keypad you have Your installer will show you how to activate these emergency keys DESCRIPTION KEYS and 7 and 9 1 and 3 See page 7 of this User Guide for pictures of the OMNI KP OMNI LCD and OMNI LED keypads ...

Page 7: ... 8 0 3 6 9 STAY BYPASS INSTANT CODE OMNI LCD AND OMNI LED KEYPADS ARMED READY 1 4 7 2 5 8 0 3 6 9 STAY BYPASS INSTANT CODE OMNI_LCD OMNI LCD Alpha Keypad 1 3 2 4 6 5 7 9 8 0 STAY INSTANT BYPASS CODE ARM AC LB READY STAY INST TX LB RF SPRV OMNI_LED OMNI LED Keypad ...

Page 8: ...ASSIGNED TO 1 MASTER USER 1 2 3 4 5 6 Duress The Master User can add change or erase other User Codes If enabled this User Code will transmit a duress signal to the central station MONITORING STATION INFORMATION Account No Telephone No ...

Page 9: ...ller you may arm the system if a delay or interior zone is faulted However faulted zones must be restored before your exit time expires or an alarm or zone bypass will result Ask your installer if your system has this feature and if so if it causes an alarm or zone bypass To Turn the System On and Leave Enter your User Code The ARMED LED goes on and the display shows LCD Keypad ON AWAY Fixed Word ...

Page 10: ... off if you plan to keep the window open for ventilation Zones that are bypassed are not protected when the system is on Refer to the paragraph entitled To Bypass a Zone for a description of the procedure To Turn the System On and Stay Inside To turn the perimeter portion of your burglar alarm on and move around freely inside the premises use the STAY mode Check to make sure the system is ready Wh...

Page 11: ...ound inside Check to make sure the system is READY When it is ready press INSTANT followed by STAY followed by your User Code When the system has been turned on successfully the ARMED LED is on and the following is displayed LCD Keypad ON STAY INS Fixed Word Keypad STAY INSTANT NOTE This system can be programmed by the installer for the AUTOSTAY feature which automatically bypasses interior zones ...

Page 12: ... on and the following is displayed LCD Keypad ON INSTANT Fixed Word Keypad INSTANT To Bypass a Zone The Bypass function excludes a zone of protection from the security system until it is unbypassed either by using the unbypass procedure or when you turn the system off Bypassing can only be done while the system is turned off Press the BYPASS button Then enter your User Code and the zone number 1 8...

Page 13: ... your User Code and Zone No 1 8 After unbypassing the zone display shows the state of the zones If the Quick Bypass feature has been enabled by the installer do not enter the User Code when unbypassing zones Turning the System Off When you turn the system off you turn off only the burglar portion of your system any smoke or heat detectors and panic keys will remain on You must enter through a desi...

Page 14: ...ed Word Keypad ARMED LED off READY LED blinks The keypad scrolls through the zone or zones that were in alarm Burglary alarms sound a steady tone at the keypad s and fire alarms generate a pulsing sound IMPORTANT If an intrusion has taken place while you were away do not enter until the location has been checked Call for help from a neighbor s house and wait there for the police To clear the displ...

Page 15: ...eate or modify other users User number 6 can be a duress code that will transmit a special duress code to the central station Deleting a User Code To delete a user press the CODE button followed by the 4 digit Master User Code Enter the user number then press to delete For example to delete user 3 do the following Master User Code User ID 1 6 to delete CODE 3 NOTE User number 1 the master user can...

Page 16: ...losings These event codes are as follows Openings 0 Closings 1 Alarm or Trouble 9 If multiple events occur the signal for the highest priority event is sent first Events ranked from highest to lowest priority are alarms trouble openings and closings XXX is depending on the event the zone 001 008 or user 001 014 designation USER DESIGNATION FUNCTION 1 6 User Codes 7 Remote arm disarm 8 Quick Arm No...

Page 17: ...ot required to enter your pager phone number If the CODE key was pressed it counts as one character The keypad will emit a single acknowledgement chirp as each number is pressed 3 Press the key after you have made your pager phone number changes Pressing the key saves your new pager number and nulls out the remaining locations An acknowledgement tone sounds To exit without saving changes press the...

Page 18: ...elp Alerts that send an emergency signal to your central station These three alerts along with their keypad combinations are shown below Fire Panic Aux 7 and 9 and 1 and 3 Duress Your system can be programmed to send an emergency signal to the central station if you are forced to enter the premises If you choose to include this feature User Code No 6 is dedicated to this function and must only be ...

Page 19: ...sarm then arm the system It is activated by pressing the STAY key while the system is armed and not in entry delay This starts the exit time causes the keypad to beep once and allows the user to exit without disarming the system The system returns to its last armed state after the exit time has expired Quick Bypass Yes No If you have Quick Bypass programmed for your system you do not have to use y...

Page 20: ...nowledge your entry a beep sounds after you set each component of the time and date Turn Chime On Off Chime is an optional feature that causes the keypad to chime when selected doors are opened when the burglary protection is off or disarmed Only your installer can program a zone for the Chime feature but once it is programmed you can turn Chime on or off to meet your daily needs To turn Chime on ...

Page 21: ...the keypad sounds the ringback tone to confirm that the signal was received 4 Turn the security system off 5 Call the central station to tell them you are finished testing Battery Test We recommend that you test your battery once a month To test your backup standby battery follow this procedure 1 Remove main power from the system 2 Observe that the AC indicator light on the keypad goes off 3 Activ...

Page 22: ...ediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that you install heat or smoke detectors in the living room dining room bedroom s kitchen hallway s attic furnace room utility and storage rooms basements and attached garages DINING KITCHEN BEDROOM BEDROOM BEDRO...

Page 23: ... and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you escape 5 Try the door If the door is hot check your alternate escape route If the door is cool open it cautiously ...

Page 24: ...s document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions ...

Page 25: ...tif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface La terminaison d une interface téléphonique peut consister en une combinaison de quelques dispositifs à la seule condition que la somme d indices d équivalence de la sonnerie de tous les dispositifs n excède pas 5 TELEPHONE OPERATIONAL PROBLEMS In the event of telephone operational problems disconnect th...

Page 26: ...recently checked during a weekly test blockage can occur if a metal object is moved into the path A user may not be able to reach a panic or emergency button quickly enough While smoke detectors have played a key role in reducing residential fire deaths they may not activate or provide early warning for a variety of reasons in as many as 35 percent of all fires Some of the reasons smoke detectors ...

Page 27: ... or any part of the optical system can reduce their detection ability Passive infrared detectors sense changes in temperature however as the ambient temperature of the protected area approaches the temperature range of 90º to 104º Fahrenheit 32º to 40º Celsius the detection performance can decrease Alarm warning devices such as sirens bells or horns may not alert people or wake up sleepers who are...

Page 28: ...at any time The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance This alarm system should be tested weekly to make sure all sensors are working properly Installing an alarm system may make one eligible for lower insurance rates but an alarm system is not a substitute for insurance Homeowners property owners and renters should continue ...

Page 29: ...rom the burglar alarm protection BYPASS KEY Keypad key used to activate the Bypass feature CENTRAL STATION Signal monitoring center contacted by your security system over the telephone and or other communication channels when alarms are activated if your system is programmed to communicate alarms off site The central station will follow their procedures and your instructions for contacting the pro...

Page 30: ...messages shows faulted zones and allows you to turn the system on off by using the keys Your system has one or more keypads ON OFF These terms refer to the burglary portion of your security system There are several operation levels that allow you to protect part of your premises while you remain inside Fire and other emergency and environmental sensors are always active and ready and are not affec...

Page 31: ... in which an audible alarm might put your life in danger those alarms are programmed as silent conditions For an example see DURESS SYSTEM Your security system is composed of three main parts 1 the control panel that functions as the system brain and the link to the monitoring agency central station 2 the keypad s that inform you of system status and allow you to input commands 3 security sensors ...

Page 32: ...OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not appl...

Reviews: